The new EK16 and EK17 Direct-Burial Ground Clamp from ERICO® is a time-saving, cost-effective versatile product that combines four clamps into one. This unique bronze-alloy grounding clamp with bronze screws consolidates separate rebar clamps, ground rod clamps, water pipe clamps and direct-burial water pipe clamps into one product, enabling contractors to save room on their trucks and distributors to save room on their shelves.

 

The UL®-listed product can be used with rebar, water pipes and ground rods. The clamp cuts installation time by allowing the contractor to pre-set the clamp on a piece of rebar or water pipe. After all of the clamps have been set, the ground conductor can then be installed using the clamp’s unique “lay-in” feature. Rather than threading the ground wire through a hole to make a continuous loop, the contractor can simply lay the conductor in the channel and tighten the setscrew without any time-consuming threading.

Features

  • Lay-in feature cuts installation time
  • Bronze alloy construction with bronze screws
  • Approved for direct burial in earth and concrete
  • Pipe range from 1/2” (12.7 mm) to 1” (25.4 mm)
  • Rebar range from #4 (10 mm) to #8 (25 mm)
  • Ground rod range from 1/2” (12.7 mm) to 1” (25.4 mm)
  • Conductor range from #10 (5.5 mm sq) to #2 (25 mm sq)
  • UL listed

Applications

Ideal for swimming pool grounding, light poles and direct-burial applications in both earth and concrete.

More Information

ORDERING INFORMATION:

 Part Number  UPC Code  Description  Qty./Box
 EK16  78285657555  Parallel direct-burial ground clamp.

 50

 EK 17  78285657558  Perpendicular direct-burial ground clamp.

 50

 

 
 Conductor Size  Rebar Size
 AWG  Metric  U.S.  Metric
 #10 - #2  5.5 mm sq. to 25 mm sq.  #4 - #8  10 mm - 25 mm

 

 

Installation is as simple as 1, 2, 3:

 

 Put the clamp on the rebar, water pipe or ground rod    Lay in the conductor    Tighten the setscrew

1. Put the clamp on the rebar, water pipe or ground rod.

2. Lay in the conductor.

3. Tighten the setscrew

 

Clamp on rebar.

Clamp on rebar Clamp on rebar  

 

Clamp on ground rod.

Clamp on ground rod Clamp on ground rod   

 

Clamp on pipe.

Clamp on pipe Clamp on pipe

UL is a registered trademark of Underwriters Laboratories, Inc.

Downloads

Related Products

Availability

North America

Due to a policy of continued product development, specifications are subject to change without notice.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.