LENTON® LOCK S-Series Mechanical Rebar Splicing System

LENTON® LOCK S-Series Mechanical Rebar Splicing SystemPrint this page

The LENTON® LOCK S-Series, part of the LENTON LOCK Mechanical Rebar Splicing System from ERICO, provides many of the same great benefits as the B-Series, except in a smaller package. All LENTON LOCK couplers feature patented gripping technology that provides overall structural integrity in tension, compression and stress-reversal applications.

With a performance that exceeds Type 1 requirements on ASTM® A706 and A615 Grade 60 rebar, this innovative mechanical rebar splice is designed for use in column splicing, bridge applications, piling, splicing to protruding dowels cast in concrete, closure pours, beams, chimney construction and other demanding splicing applications.

The couplers allow for easy field installation since no bar-end preparation, sawing or swaging is necessary, and they can be installed with just a standard wrench or an impact wrench, depending on coupler size. The bolt heads will shear off when proper installation tightness has been reached, which allows for complete visual inspection.

The S-Series is ideal for use in repair, bent bar, retrofit, precast closure pour and new construction applications. The couplers meet or exceed major international building codes and Department of Transportation requirements, including ACI® 318 Type 1, UBC® Type 1 and IBC® Type 1.

LENTON LOCK works as a one-step transition on ASTM (in-lb) and metric rebar. For Canadian rebar sizes, contact ERICO for transition compatibility.

Features

  • Meets or exceeds major international building codes and Department of Transportation requirements, including ACI® 318 Type 1, UBC® Type 1 and IBC® Type 1
  • For use with rebar meeting ASTM A706 or ASTM A615 grades 40 and 60
  • Uses standard rebar; requires no bar-end preparation, such as sawing or swaging, and is ideal for in-situ splices
  • Is smaller than other bolted splices currently available
  • Works in repair, bent bar, retrofit, precast closure pour and new construction applications
  • Installs quickly and easily using simple hand tools; does not require special skilled labor
  • Allows for simple visual inspection
  • Works as one-step transition on ASTM (in-lb) and metric rebar
  • Epoxy coating available

Applications

LENTON® LOCK S-Series is ideal for column splicing, bridge applications, piling, splicing to protruding dowels cast in concrete, closure pours, beams, chimney construction and other demanding splicing applications.

More Information

Simple 1-2-3 Installation:

1.Insert the LENTON LOCK coupler over reinforcing bar 1.2.Tighten bolts from the center
to the end to secure onto the
first reinforcing bar. (impact wrench shown*)
3.Repeat steps 1 & 2 with the second reinforcing bar on the other side of the coupler.

Rebar Designation
Part
No.
Length
Outside
Diameter
Inside
Diameter
Weight
Socket
Size
Avg. Bolt
Torque
No. of
Bolts
Standard
Packaging
Qty.
ASTM
metric
Can.
Soft
Metric
in
mm
in
mm
in
mm
lbs
kg
in
mm
ft-lb
N-m
#4
10; 12
10M
13; 10
LL12S1
3.9
99
1,3
29
0.6
15
1.3
0.5
1/2
13
145
200
4
60
#514; 1615M
16
LL16S14.3
109
1.4
35
0.7
19
1.4
0.6
1/2
13
145
200
4
30
#618; 2020M
19
LL20S1
6
153
1.6
41
0.9
24
2.0
1.1
1/2
13
145
200
6
20
#722
-22
LL22S16.8
173
1.8
48
1.1
28
3.3
1.8
5/8
16
240
325
6
12
#82525M25
LL25S1
6.8
173
2.1
54
1.2
30
4.3
2.3
5/8
16
340
460
6
12
#928; 3030M29
LL28S1
6.8
173
2.3
60
1.3
34
5.3
2.8
5/8
16
340
460
6
6
#1032
-32
LL32S1
8.7
220
2.5
65
1.5
38
8.4
4.0
13/16
21
550
745
6
4
#1134; 3635M36
LL36S1
11.2
286
2.8
72
1.7
43
12.6
6.2
13/16
21
550
745
8
3
#14
43
45M
43LL43S1
16.5
418
3.5
89
2.1
53
29.8
13.6
13/16
21
660
895
12
1
#18
57
55M
57
LL57S1
22.5
572
4.5
117
2.6
67
69.9
33.8
1
25
960
1300
14
1

Note: Dimensions are typical.  Bolt length may vary after the bolt heads are sheared off.


*When using an air impact wrench it is recommended to use a wrench with double the torque rating identified.
Impact sockets should always be used when using an impact wrench.
Additionally, check the air pressure and air flow requirements prior to installation.
Refer to complete installation instructions provided with the product or available at www.erico.com prior to commencing installation.


ACI  is a registered trademark of the American Concrete Institute
UBC is a registered trademark of the International Conference of Building Officials Corporation
IBC is a registered trademark of the International Code Council
ASTM is a registered trademark of the ASTM International


Related Products

Availability

North America

Due to a policy of continued product development, specifications are subject to change without notice.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.