Where to BuyNews and EventsCareersContact Us
  All CountriesChange

Datasheets, Brochures and Catalog Sections

Availability
North America
Latin America
Asia/Australia
Europe/Middle East/Africa
Water Pipe Clamps

Water Pipe ClampsPrint this page

In addition to CADWELD®  exothermic connections, ERICO also offers mechanical connectors for applications that do not warrant a welded connection.

Features

  • Bronze & Zinc Water Pipe Clamps
    • Ideal for connecting copper conductors to metallic water pipe (including copper tubing) or ground rods
    • Bond corrugated stainless steel tubing (CSST) or flexible gas pipe systems to the electrical system in accordance with the NFGC® (National Fuel Gas Code) and the NEC® (National Electric Code)
    • Applications include lightning protection, fault current ground, signal reference grid and static ground
    • CWP series of clamps fits hex fittings, copper grounding conductors, galvanized water pipes, copper water tubing or copper ground rods ranging from 1/2" to 4"
    • High-strength silicone bronze clamps connect brass hex fittings
    • UL® Listed (ANSI®/UL 467 - Category KDER)

Applications

Applications include lightning protection, fault current ground, signal reference grid and static ground.

More Information

Water Pipe Clamps
Part No. Description Ø (in)

Std Box Qty

Weight per 100
CWP1J Bronze, #10 Sol - #2 Sol 1/2 - 1 100 21
CWP1JJ Bronze, #10 Sol - #4 Str 1/2 - 1 100 16
CWP2J Bronze, #10 Sol - #2 Str 1 1/4 - 2 50 46
CWP3J and CWP4J Bronze, #10 Sol - #4 Str 2 1/2 - 4 20
115
CWP6J Bronze, #10 Sol - #4 Str 4 1/4 - 6 20 186
CWP1JU Bronze, #10 Sol - #2 Sol 1/2 - 1 100 21
CWP2JU Bronze, #10 Sol - #2 Str 1 1/4 - 2 50 45
ZWP1J Zinc, #8 Sol - #2 Str 1/2 - 1 200 15
EGC1 Aluminum, #14 Sol - 1/0 Str 1/2 - 1 25 12

Water Pipe Clamp Assemblies
Part No. Cable Size
B852A12C1X-"L" #1 Solid
B852A12C1Y-"L" #1 Stranded
B852A12C2C-"L" 1/0 AWG
B852A12C2G-"L" 2/0 AWG
B852A12C2Q-"L" 4/0 AWG
B852A12C2V-"L" 250 kcmil
Clamp fits 3" to 12" pipe. "L" = Cable stub length up to 24 inches. For lengths greater than 24", contact ERICO.

UL is a registered trademark of Underwriters Laboratories, Inc.
NFPA is a registered trademark of the National Fire Protection Association.
NEC is a registered trademark of, and National Electrical Code (NEC) standard is a copyright of the National Fire Protection Association.
NFGC is a registered trademark of, and National Fuel Gas Code (NFGC) standard is a copyright of the National Fire Protection Association
ANSI is a registered trademark of the American National Standards Institute.

Due to a policy of continued product development, specifications are subject to change without notice.

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

  Warning, Warranty and Limitation of Liability

 