Water Pipe Clamps

Water Pipe ClampsPrint this page

In addition to CADWELD®  exothermic connections, ERICO also offers mechanical connectors for applications that do not warrant a welded connection.

Features

  • Bronze & Zinc Water Pipe Clamps
    • Ideal for connecting copper conductors to metallic water pipe (including copper tubing) or ground rods
    • Bond corrugated stainless steel tubing (CSST) or flexible gas pipe systems to the electrical system in accordance with the NFGC® (National Fuel Gas Code) and the NEC® (National Electric Code)
    • Applications include lightning protection, fault current ground, signal reference grid and static ground
    • CWP series of clamps fits hex fittings, copper grounding conductors, galvanized water pipes, copper water tubing or copper ground rods ranging from 1/2" to 4"
    • High-strength silicone bronze clamps connect brass hex fittings
    • UL® Listed (ANSI®/UL 467 - Category KDER)

Applications

Applications include lightning protection, fault current ground, signal reference grid and static ground.

More Information

Water Pipe Clamps
Part No. Description Ø (in)

Std Box Qty

Weight per 100
CWP1J Bronze, #10 Sol - #2 Sol 1/2 - 1 100 21
CWP1JJ Bronze, #10 Sol - #4 Str 1/2 - 1 100 16
CWP2J Bronze, #10 Sol - #2 Str 1 1/4 - 2 50 46
CWP3J and CWP4J Bronze, #10 Sol - #4 Str 2 1/2 - 4 20
115
CWP6J Bronze, #10 Sol - #4 Str 4 1/4 - 6 20 186
CWP1JU Bronze, #10 Sol - #2 Sol 1/2 - 1 100 21
CWP2JU Bronze, #10 Sol - #2 Str 1 1/4 - 2 50 45
ZWP1J Zinc, #8 Sol - #2 Str 1/2 - 1 200 15
EGC1 Aluminum, #14 Sol - 1/0 Str 1/2 - 1 25 12

Water Pipe Clamp Assemblies
Part No. Cable Size
B852A12C1X-"L" #1 Solid
B852A12C1Y-"L" #1 Stranded
B852A12C2C-"L" 1/0 AWG
B852A12C2G-"L" 2/0 AWG
B852A12C2Q-"L" 4/0 AWG
B852A12C2V-"L" 250 kcmil
Clamp fits 3" to 12" pipe. "L" = Cable stub length up to 24 inches. For lengths greater than 24", contact ERICO.

UL is a registered trademark of Underwriters Laboratories, Inc.
NFPA is a registered trademark of the National Fire Protection Association.
NEC is a registered trademark of, and National Electrical Code (NEC) standard is a copyright of the National Fire Protection Association.
NFGC is a registered trademark of, and National Fuel Gas Code (NFGC) standard is a copyright of the National Fire Protection Association
ANSI is a registered trademark of the American National Standards Institute.

Downloads

Due to a policy of continued product development, specifications are subject to change without notice.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.