Theft-deterrent composite cables (TDCC) are conductors that function as copper conductors, but appear to be non-copper conductors and are difficult to cut and steal. These conductors are ideal for exposed electrical distribution grounding leads where copper theft may occur. Theft deterrent conductors are difficult to cut with hand tools and the outer steel stranding is magnetic, which further deters thieves looking for copper.

Theft-deterrent cables conductors are either bare or insulated concentric stranded conductors that consist of outer galvanized steel strands that protect and conceal internal tinned copper strands.

Smaller diameter conductors such as a #4 AWG equivalent are ideal for transmission tower, distribution pole and streetlight grounding applications. Larger sizes such as the conductor equivalents to either 2/0 or 4/0 copper conductors are suitable for a wide range of grounding applications.

Features

  • Inner copper stranding is tinned for superior corrosion resistance
  • Inner copper core provides increased conductivity and flexibility
  • More flexible and easier to work with than copper clad steel conductors

Specifications

Material: Copper; Steel
Finish: Tinned; Electrogalvanized
Insulated: No
Part Number Stranding Resistance Fusing Capacity Equivalency Insulation Thickness Cable Diameter Cable Length Unit Weight
CC5A04 (1) Tinned Copper, (6) Galvanized Steel 0.485 Ω/1000' #4 0.330" 250' 57 lb
CC5A05 (3) Tinned Copper, (16) Galvanized Steel 0.457 Ω/1000' #4 0.334" 250' 58 lb
CC5A05300M (3) Tinned Copper, (16) Galvanized Steel 0.457 Ω/1000' #4 0.334" 984' 233 lb
CC5A05500M (3) Tinned Copper, (16) Galvanized Steel 0.457 Ω/1000' #4 0.334" 1,640' 389 lb
CC5A05SP100M (3) Tinned Copper, (16) Galvanized Steel 0.457 Ω/1000' #4 0.334" 328' 90 lb
CC5A20 (133) Tinned Copper, (21) Galvanized Steel 0.098 Ω/1000' 2/0 0.526" 200' 109 lb
CC5A30 (133) Tinned Copper, (24) Galvanized Steel 0.076 Ω/1000' 3/0 0.572" 200' 135 lb
CC5A40 (133) Tinned Copper, (28) Galvanized Steel 0.057 Ω/1000' 4/0 0.656" 200' 172 lb
Insulated: Yes
Part Number Stranding Resistance Fusing Capacity Equivalency Insulation Thickness Cable Diameter Cable Length Unit Weight
CC5A20INS (133) Tinned Copper, (21) Galvanized Steel 0.098 Ω/1000' 2/0 0.095" 0.526" 200' 135 lb
CC5A20INSK (133) Tinned Copper, (21) Galvanized Steel 0.098 Ω/1000' 2/0 0.095" 0.526" 1,000' 636 lb
CC5A30INS (133) Tinned Copper, (24) Galvanized Steel 0.076 Ω/1000' 3/0 0.095" 0.572" 200' 151 lb
CC5A30INSK (133) Tinned Copper, (24) Galvanized Steel 0.076 Ω/1000' 3/0 0.095" 0.572" 1,000' 677 lb
CC5A40INS (133) Tinned Copper, (28) Galvanized Steel 0.057 Ω/1000' 4/0 0.095" 0.656" 200' 200 lb
CC5A40INSK (133) Tinned Copper, (28) Galvanized Steel 0.057 Ω/1000' 4/0 0.095" 0.656" 1,000' 936 lb
Weight does not include reel.