Coaxial Surge Protector

Features

  • Simple plug-in installation
  • Supplied with mounting bracket and flying lead ground
  • Low insertion and return loss
  • Wide operating frequency spectrum

Specifications

Max Discharge Current (Imax), Per Mode: 20 kA 8/20 μs
Frequency: 0 – 3 GHz
Capacitance: 1.5 pF
Insulation Resistance: 10 GΩ
Impulse Life: 400 @ 500 A 10/1000 μs
Enclosure Material: Metal
Enclosure Rating: IP 20; NEMA®-1
Temperature: -40 to 194 °F
Connection Type: BNC, Male/Female
Part Number Spark-Over Voltage @ 100 V/μs Spark-Over Voltage @ 100 V/s DepthD HeightH WidthW Unit Weight
CSP1BNC90 450 V 72 – 108 V 1" 0.984" 0.984" 0.294 lb
CSP1BNC600 1,100 V 480 – 720 V 1" 0.984" 0.984" 0.294 lb
Connection Type: F-Type, Male/Female
Part Number Spark-Over Voltage @ 100 V/μs Spark-Over Voltage @ 100 V/s DepthD HeightH WidthW Unit Weight
CSP1F90 450 V 72 – 108 V 1" 0.984" 0.984" 0.294 lb
CSP1F600 1,100 V 480 – 720 V 1" 0.984" 0.984" 0.294 lb
Connection Type: N-Bulkhead, Male/Female
Part Number Spark-Over Voltage @ 100 V/μs Spark-Over Voltage @ 100 V/s DepthD HeightH WidthW Unit Weight
CSP1NBM90 450 V 72 – 108 V 1" 0.984" 0.984" 0.294 lb
CSP1NBM600 1,100 V 480 – 720 V 1" 0.984" 0.984" 0.294 lb
Connection Type: N-Type, Female/Female
Part Number Spark-Over Voltage @ 100 V/μs Spark-Over Voltage @ 100 V/s DepthD HeightH WidthW Unit Weight
CSP1NB90 450 V 72 – 108 V 1" 0.984" 0.984" 0.294 lb
CSP1NB600 1,100 V 480 – 720 V 1" 0.984" 0.984" 0.294 lb
Connection Type: N-Type, Male/Female
Part Number Spark-Over Voltage @ 100 V/μs Spark-Over Voltage @ 100 V/s DepthD HeightH WidthW Unit Weight
CSP1NMF90 450 V 72 – 108 V 1" 0.984" 0.984" 0.294 lb
CSP1NMF600 1,100 V 480 – 720 V 1" 0.984" 0.984" 0.294 lb
Connection Type: SMA, Male/Female
Part Number Spark-Over Voltage @ 100 V/μs Spark-Over Voltage @ 100 V/s DepthD HeightH WidthW Unit Weight
CSP1SMA90 450 V 72 – 108 V 1" 0.984" 0.984" 0.294 lb
CSP1SMA600 1,100 V 480 – 720 V 1" 0.984" 0.984" 0.294 lb

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

NEMA is a registered service mark of National Electrical Manufacturers Association.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Brochures

Catalogs

Certifications

UL QVLA.E355701
UL Subject 497E

Datasheets

Technical

Warranties