ERIFLEX

ERIFLEX FLEXIBAR, Tinned Copper

Features

  • Thin layers of tinned electrolytic copper formed into a stack
  • Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility
  • Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint
  • Dramatically smaller and more flexible than comparable cable based on ampacity
  • Better power density than cable with lower skin effect ratio
  • Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the ERIFLEX FLEXIBAR, or welding using ERICO CADWELD
  • No lugs needed, reducing installation time and improving resistance to vibration
  • Weight savings and material savings compared to wire alternatives
  • Reduces total installation cost
  • Traceability codes and designation part numbers printed on insulation
  • 100% production dielectric tested
  • UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F)
  • EAC compliant
  • RoHS compliant

Specifications

Typical Application Current Rating
Finish: Tinned
Material: Copper; Polyvinylchloride
Dielectric Strength: 20 kV/mm
Flammability Rating: UL® 94V-0
Insulation Elongation: 370 %
Insulation Thickness: 0.08"
Nominal Voltage, UL/IEC: 1,000 VAC; 1,500 VDC
Operating Temperature: -58 to 221 °F
Forming Temperature: 32 – 131 °F
Complies With: IEC® 60439.1; IEC® 61439.1; IEC® 61439.1 Class II
Typical Application Current Rating: 125 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX2MTC3X9X0-8 505051 6.56 126 158 185 3 0.354 0.031 42.63 1.72 2.25
FLEX2MTC3X13 505053 6.56 128 160 187 3 0.512 0.020 38.48 1.72 2.25
FLEX2MTC2X15-5 505059 6.56 152 190 222 2 0.610 0.031 48.94 1.72 2.25
FLEX2MTC6X13 505054 6.56 188 235 275 6 0.512 0.020 77.00 1.72 2.25
FLEX2MTC6X9X0-8 505052 6.56 192 241 281 6 0.354 0.031 85.26 1.72 2.25
Typical Application Current Rating: 250 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX2MTC4X16 505055 6.56 223 279 326 4 0.610 0.031 97.89 1.72 2.25
FLEX2MTC6X16 505056 6.56 282 353 412 6 0.610 0.031 146.83 1.72 2.25
FLEX3MTC2X20X1 505501 9.84 211 263 307 2 0.787 0.039 78.94 1.72 2.25
FLEX3MTC2X24X1 505506 9.84 244 305 357 2 0.945 0.039 94.73 1.72 2.25
FLEX3MTC3X20X1 505502 9.84 263 328 383 3 0.787 0.039 118.41 1.72 2.25
FLEX3MTC3X24X1 505507 9.84 304 379 443 3 0.945 0.039 142.10 1.72 2.25
FLEX3MTC4X20X1 505503 9.84 308 385 450 4 0.787 0.039 157.88 1.72 2.25
FLEX3MTC2X32X1 505513 9.84 311 385 454 2 1.260 0.039 126.30 1.72 2.25
Typical Application Current Rating: 400 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX3MTC5X20X1 505504 9.84 351 438 512 5 0.787 0.039 197.35 1.72 2.25
FLEX3MTC4X24X1 505508 9.84 356 445 520 4 0.945 0.039 189.46 1.72 2.25
FLEX3MTC3X32X1 505514 9.84 385 481 562 3 1.260 0.039 189.46 1.72 2.25
FLEX3MTC6X20X1 505505 9.84 390 487 569 6 0.787 0.039 236.80 1.72 2.25
FLEX3MTC5X24X1 505509 9.84 403 504 589 5 0.945 0.039 236.80 1.72 2.25
FLEX3MTC6X24X1 505510 9.84 448 559 653 6 0.945 0.039 284.19 1.72 2.25
FLEX3MTC4X32X1 505515 9.84 449 561 665 4 1.260 0.039 252.60 1.72 2.25
FLEX3MTC3X40X1 505521 9.84 464 580 677 3 1.575 0.039 236.80 1.72 2.25
FLEX3MTC5X32X1 505516 9.84 507 633 740 5 1.260 0.039 315.70 1.72 2.25
FLEX3MTC8X24X1 505511 9.84 531 663 775 8 0.945 0.039 378.90 1.72 2.25
FLEX3MTC4X40X1 505522 9.84 541 675 789 4 1.575 0.039 315.70 1.72 2.25
FLEX3MTC6X32X1 505517 9.84 561 701 819 6 1.260 0.039 378.90 1.72 2.25
FLEX3MTC3X50X1 505527 9.84 562 702 820 3 1.969 0.039 296.03 1.72 2.25
FLEX3MTC10X24X1 505512 9.84 606 757 885 10 0.945 0.039 473.65 1.72 2.25
FLEX3MTC5X40X1 505523 9.84 608 759 887 5 1.575 0.039 394.70 1.72 2.25
Typical Application Current Rating: 800 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX3MTC4X50X1 505528 9.84 651 813 950 4 1.969 0.039 394.70 1.72 2.25
FLEX3MTC8X32X1 505518 9.84 657 821 959 8 1.260 0.039 505.22 1.72 2.25
FLEX3MTC6X40X1 505524 9.84 669 835 976 6 1.575 0.039 473.65 1.72 2.25
FLEX3MTC3X63X1 505533 9.84 687 857 1,002 3 2.480 0.039 373.00 1.65 2.12
FLEX3MTC5X50X1 505529 9.84 730 911 1,065 5 1.969 0.039 493.38 1.72 2.25
FLEX3MTC6X45X1 505551 9.84 736 919 1,074 6 1.772 0.039 532.85 1.72 2.25
FLEX3MTC10X32X1 505519 9.84 745 931 1,088 10 1.260 0.039 631.50 1.72 2.25
FLEX3MTC8X40X1 505525 9.84 786 981 1,146 8 1.575 0.039 631.50 1.72 2.25
FLEX3MTC4X63X1 505534 9.84 792 988 1,155 4 2.480 0.039 497.33 1.65 2.12
FLEX3MTC6X50X1 505530 9.84 802 1,002 1,171 6 1.969 0.039 592.06 1.72 2.25
FLEX3MTC10X40X1 505526 9.84 879 1,097 1,282 10 1.575 0.039 789.41 1.72 2.25
FLEX3MTC5X63X1 505535 9.84 883 1,102 1,288 5 2.480 0.039 621.66 1.65 2.12
FLEX3MTC8X50X1 505531 9.84 927 1,157 1,352 8 1.969 0.039 789.41 1.72 2.25
Typical Application Current Rating: 1,200 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX3MTC6X63X1 505536 9.84 966 1,205 1,408 6 2.480 0.039 746.00 1.65 2.12
FLEX3MTC4X80X1 505540 9.84 970 1,211 1,415 4 3.150 0.039 631.50 1.65 2.12
FLEX3MTC10X50X1 505532 9.84 1,040 1,298 1,517 10 1.969 0.039 986.76 1.72 2.25
FLEX3MTC5X80X1 505541 9.84 1,077 1,344 1,570 5 3.150 0.039 789.41 1.65 2.12
FLEX3MTC8X63X1 505537 9.84 1,108 1,383 1,616 8 2.480 0.039 994.66 1.65 2.12
FLEX3MTC6X80X1 505542 9.84 1,172 1,463 1,709 6 3.150 0.039 947.30 1.65 2.12
FLEX3MTC10X63X1 505538 9.84 1,232 1,538 1,797 10 2.480 0.039 1,243.30 1.65 2.12
Typical Application Current Rating: 1,600 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX3MTC5X100X1 505546 9.84 1,301 1,624 1,898 5 3.937 0.039 986.76 1.60 2.02
FLEX3MTC8X80X1 505543 9.84 1,341 1,674 1,956 8 3.150 0.039 1,263.06 1.65 2.12
FLEX3MTC6X100X1 505547 9.84 1,414 1,765 2,062 6 3.937 0.039 1,184.12 1.60 2.02
FLEX3MTC10X80X1 505544 9.84 1,484 1,851 2,164 10 3.150 0.039 1,578.80 1.65 2.12
FLEX3MTC8X100X1 505548 9.84 1,598 1,994 2,330 8 3.937 0.039 1,578.80 1.60 2.02
Typical Application Current Rating: 2,000 A
Certification Details: UL® 67
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX3MTC12X100 505550 9.84 1,920 2,396 2,800 12 3.937 0.039 2,368.23 1.60 2.02
Typical Application Current Rating: 2,000 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient
FLEX3MTC10X100 505549 9.84 1,765 2,203 2,574 10 3.937 0.039 1,973.52 1.60 2.02
ADMISSIBLE CURRENTS: This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear.
∆T = Temperature of conductors – Internal temperature of panel.
Refer to technical documentation for additional ampacity ratings.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

ABS is a registered certification mark of American Bureau of Shipping.
CSA, CSA-US and C-CSA-US are registered trademarks of Canadian Standards Association.
IEC is a registered trademark of the International Electrotechnical Commission.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Video

Brochures

Catalogs

Flexible Conductors
63.23 MB English

Certifications

Bureau Veritas 02859 BV
ACE 14/163/02, 262 KB English
CSA 90005
CSA C22.2 No. 0, CSA C22.2 No. 210
cUR QEUY8.E125470
CSA C22.2 No. 29, CSA C22.2 No. 244
IEC 61439-1 Class II FLEXIBAR
IEC 61439-1 (2011), EN 61439-1 (2012), 50 KB English
IEC 61439-1 FLEXIBAR
IEC 61439-1 (2012), 50 KB English
UR AVLV2.E316390
ANSI/UL 758
UR QEUY2.E125470
ANSI/UL 67, ANSI/UL 891

Datasheets