United StatesChange
ERICO

ERICO CADWELD MULTI Multiple Connection Type Mold Kit

Features

  • Versatile mold produces a variety of connections
  • Patented, self-sealing system prevents weld metal leakage
  • Compact compression structure enables easy alignment of conductors
  • Language-free instruction guide
  • Easy-to-use system completes welds in seconds

Specifications

Part Number
KITCDMV01
Types of ERICO CADWELD MULTI Multiple Connectors
Mold 
Style
Number 
of 
Battings 
Required
Maximum 
Conductor 
Size
Maximum 
Bus/Lug 
Size
Maximum 
Rebar 
Size, 
Metric
Maximum 
Rebar 
Size, 
US
Ground 
Rod 
Diameter, 
Nominal
Ground 
Rod 
Diameter, 
Actual
Solid or Stranded Copper Cable to Solid or Stranded Copper Cable
SS 2 50 mm² Str; 1/0 Str - - - - -
SC 2 50 mm² Str; 1/0 Str - - - - -
PA 2 50 mm² Str; 1/0 Str - - - - -
PA 2 50 mm² Str; 1/0 Str - - - - -
XA 2 50 mm² Str; 1/0 Str - - - - -
GG 2 50 mm² Str; 1/0 Str - - - - -
GJ 2 50 mm² Str; 1/0 Str - - - - -
GF 2 50 mm² Str; 1/0 Str - - - - -
GW 2 50 mm² Str; 1/0 Str - - - - -
XB 3 50 mm² Str; 1/0 Str - - - - -
PP 2 50 mm² Str; 1/0 Str - - - - -
PK 2 50 mm² Str; 1/0 Str - - - - -
GE 2 50 mm² Str; 1/0 Str - - - - -
PG 2 50 mm² Str; 1/0 Str - - - - -
TD 2 25 mm² Str; #4 Str - - - - -
TE 2 25 mm² Str; #4 Str - - - - -
TF 2 25 mm² Str; #4 Str - - - - -
Solid or Stranded Copper Cable to Rebar
RG 2 50 mm² Str; 1/0 Str - 10 mm #3 - -
RH 2 50 mm² Str; 1/0 Str - 10 mm #3 - -
RK 2 50 mm² Str; 1/0 Str - 10 mm #3 - -
RD 3 50 mm² Str; 1/0 Str - 10 mm #3 - -
Copper or Steel Strip to Rebar
RF 2 - 1.2" X 0.14" 10 mm #3 - -
Copper Strip to Copper Strip
BB 2 - 1.2" X 0.14" - - - -
CG 3 - 1.2" X 0.14" - - - -
BG 3 - 1.2" X 0.12" - - - -
EB 3 - 1.2" X 0.12" - - - -
Solid or Stranded Copper Cable to Copper or Steel Bus/Lug
HA 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
HC 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
HS 3 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
HT 3 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
GL 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
LA 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
LJ 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
LE 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
Galvanized Steel Strip to Galvanized Steel Strip
BB 2 - 1.2" X 0.12" - - - -
CG 3 - 1.2" X 0.12" - - - -
Solid or Stranded Copper Cable to Ground Rods
TG 2 10mm² Str; #6 Str - - - 1/2"-3/4" 0.5"-0.682"
GT 2 10mm² Str; #6 Str - - - 1/2"-3/4" 0.5"-0.682"
GR 2 10mm² Str; #6 Str - - - 1/2"-3/4" 0.5"-0.682"
GT 3 10mm² Str; #6 Str - - - 1/2"-3/4" 0.5"-0.682"
GR 3 10mm² Str; #6 Str - - - 1/2"-3/4" 0.5"-0.682"
Copper Strip to Ground Rod
CN 2 - 1.2" X 0.14" - - 1/2"-3/4" 0.5"-0.682"
CP 2 - 1.2" X 0.14" - - 1/2"-3/4" 0.5"-0.682"
CN 3 - 1.2" X (0.10"-0.14") - - 1/2"-3/4" 0.5"-0.682"
CP 3 - 1.2" X (0.10"-0.14") - - 1/2"-3/4" 0.5"-0.682"
Galvanized Steel Strip to Ground Rod
CN 3 - 1.2" X (0.02"-0.14") - - 1/2"-3/4" 0.5"-0.682"
CP 3 - 1.2" X (0.02"-0.14") - - 1/2"-3/4" 0.5"-0.682"

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

Applications