United StatesChange
nVent ERICO

nVent ERICO Cadweld Multi Multiple Connection Type Mold Kit

Features

  • Versatile mold produces a variety of connections
  • Patented, self-sealing system prevents weld metal leakage
  • Compact compression structure enables easy alignment of conductors
  • Language-free instruction guide
  • Easy-to-use system completes welds in seconds

Specifications

Part Number
KITCDMV01
Types of ERICO CADWELD MULTI Multiple Connectors
Mold Style Number of Battings Required Maximum Conductor Size Maximum Bus/Lug Size Maximum Rebar Size, Metric Maximum Rebar Size, US Ground Rod Diameter, Nominal Ground Rod Diameter, Actual
Solid or Stranded Copper Cable to Solid or Stranded Copper Cable
SS 2 50 mm² Str; 1/0 Str - - - - -
SC 2 50 mm² Str; 1/0 Str - - - - -
PA 2 50 mm² Str; 1/0 Str - - - - -
PA 2 50 mm² Str; 1/0 Str - - - - -
XA 2 50 mm² Str; 1/0 Str - - - - -
GG 2 50 mm² Str; 1/0 Str - - - - -
GJ 2 50 mm² Str; 1/0 Str - - - - -
GF 2 50 mm² Str; 1/0 Str - - - - -
GW 2 50 mm² Str; 1/0 Str - - - - -
XB 3 50 mm² Str; 1/0 Str - - - - -
PP 2 50 mm² Str; 1/0 Str - - - - -
PK 2 50 mm² Str; 1/0 Str - - - - -
GE 2 50 mm² Str; 1/0 Str - - - - -
PG 2 50 mm² Str; 1/0 Str - - - - -
TD 2 25 mm² Str; #4 Str - - - - -
TE 2 25 mm² Str; #4 Str - - - - -
TF 2 25 mm² Str; #4 Str - - - - -
Solid or Stranded Copper Cable to Rebar
RG 2 50 mm² Str; 1/0 Str - 10 mm #3 - -
RH 2 50 mm² Str; 1/0 Str - 10 mm #3 - -
RK 2 50 mm² Str; 1/0 Str - 10 mm #3 - -
RD 3 50 mm² Str; 1/0 Str - 10 mm #3 - -
Copper or Steel Strip to Rebar
RF 2 - 1.2" X 0.14" 10 mm #3 - -
Copper Strip to Copper Strip
BB 2 - 1.2" X 0.14" - - - -
CG 3 - 1.2" X 0.14" - - - -
BG 3 - 1.2" X 0.12" - - - -
EB 3 - 1.2" X 0.12" - - - -
Solid or Stranded Copper Cable to Copper or Steel Bus/Lug
HA 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
HC 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
HS 3 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
HT 3 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
GL 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
LA 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
LJ 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
LE 2 50 mm² Str; 1/0 Str 1.2" X 0.14" - - - -
Galvanized Steel Strip to Galvanized Steel Strip
BB 2 - 1.2" X 0.12" - - - -
CG 3 - 1.2" X 0.12" - - - -
Solid or Stranded Copper Cable to Ground Rods
TG 2 10 mm² Str; #6 Str - - - 1/2" - 3/4" 0.5" - 0.682"
GT 2 10 mm² Str; #6 Str - - - 1/2" - 3/4" 0.5" - 0.682"
GR 2 10 mm² Str; #6 Str - - - 1/2" - 3/4" 0.5" - 0.682"
GT 3 10 mm² Str; #6 Str - - - 1/2" - 3/4" 0.5" - 0.682"
GR 3 10 mm² Str; #6 Str - - - 1/2" - 3/4" 0.5" - 0.682"
Copper Strip to Ground Rod
CN 2 - 1.2" X 0.14" - - 1/2" - 3/4" 0.5" - 0.682"
CP 2 - 1.2" X 0.14" - - 1/2" - 3/4" 0.5" - 0.682"
CN 3 - 1.2" X (0.10" - 0.14") - - 1/2" - 3/4" 0.5" - 0.682"
CP 3 - 1.2" X (0.10" - 0.14") - - 1/2" - 3/4" 0.5" - 0.682"
Galvanized Steel Strip to Ground Rod
CN 3 - 1.2" X (0.02" - 0.14") - - 1/2" - 3/4" 0.5" - 0.682"
CP 3 - 1.2" X (0.02" - 0.14") - - 1/2" - 3/4" 0.5" - 0.682"

nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

Applications