United StatesChange
ERICO

Ground Point Assembly

Features

  • Convenient ground system connection points in concrete structures
  • Used for equipment, machinery and structure grounding
  • Results in maximum current-carrying capacity equal to the cross-sectional area of the conductor or stud
  • The ERICO CADWELD connection between the stud and pigtail will not loosen or corrode

Specifications

B530-A-2Q-72
B530 Ground Plate Configuration B530 = RA
B531 = RB
B532 = SS
B533 = TA
A Ground Plate Part Number A = B1612Q
B = B1613Q
C = B1622Q
D = B1642Q
E = B1643Q
2Q Cable Code 1G = #6 Solid
1L = #4 Stranded
1V = #2 Stranded
2C = 1/0 Stranded
2G = 2/0 Stranded
2Q = 4/0 Stranded
2V = 250 MCM Stranded
3D = 350 MCM Stranded
3Q = 500 MCM Stranded
72 Cable Length (inches)

Search

The search below may not contain all product options. For made-to-order configurations, consult the chart above.

Ground Plate Configuration
Ground Plate Part Number
Conductor Size
Cable Length

Ground Plate Configuration

Ground Plate Part Number

Material: Copper Alloy
Part Number Ground Plate Configuration Ground Plate Part Number Conductor Size Cable Length
B530A1L12 RA B1612Q #4 Stranded 12"
B530A1V12 RA B1612Q #2 Stranded 12"
B530A2Q48 RA B1612Q 4/0 Stranded 48"
B530A2Q72 RA B1612Q 4/0 Stranded 72"
B530B2G24 RA B1613Q 2/0 Stranded 24"
B530C1L048 RA B1622Q #4 Stranded 48"
B530C2C24 RA B1622Q 1/0 Stranded 24"
B530C2G48 RA B1622Q 2/0 Stranded 48"
B530C2Q36 RA B1622Q 4/0 Stranded 36"
B530C2Q48 RA B1622Q 4/0 Stranded 48"
B530C2Q96 RA B1622Q 4/0 Stranded 96"
B530D2C48 RA B1642Q 1/0 Stranded 48"
B530D2G18 RA B1642Q 2/0 Stranded 18"
B530D2G180 RA B1642Q 2/0 Stranded 180"
B530D2G24 RA B1642Q 2/0 Stranded 24"
B530D2G48 RA B1642Q 2/0 Stranded 48"
B530D2Q12 RA B1642Q 4/0 Stranded 12"
B530D2Q120 RA B1642Q 4/0 Stranded 120"
B530D2Q144 RA B1642Q 4/0 Stranded 144"
B530D2Q180 RA B1642Q 4/0 Stranded 180"
B530D2Q24 RA B1642Q 4/0 Stranded 24"
B530D2Q32 RA B1642Q 4/0 Stranded 32"
B530D2Q36 RA B1642Q 4/0 Stranded 36"
B530D2Q48 RA B1642Q 4/0 Stranded 48"
B530D2Q72 RA B1642Q 4/0 Stranded 72"
B530D2Q96 RA B1642Q 4/0 Stranded 96"
B531A2Q36 RB B1612Q 4/0 Stranded 36"
B531D2G24 RB B1642Q 2/0 Stranded 24"
B531D2Q12 RB B1642Q 4/0 Stranded 12"
B531D2Q120 RB B1642Q 4/0 Stranded 120"
B531D2Q144 RB B1642Q 4/0 Stranded 144"
B531D2Q24 RB B1642Q 4/0 Stranded 24"
B531D2Q48 RB B1642Q 4/0 Stranded 48"
B531D2Q6 RB B1642Q 4/0 Stranded 6"
B531D2Q72 RB B1642Q 4/0 Stranded 72"
B531D2Q96 RB B1642Q 4/0 Stranded 96"
B532A2Q48 SS B1612Q 4/0 Stranded 48"
B532C2G24 SS B1622Q 2/0 Stranded 24"
B532C2G60 SS B1622Q 2/0 Stranded 60"
B532C2Q240 SS B1622Q 4/0 Stranded 240"
B532C2Q48 SS B1622Q 4/0 Stranded 48"
B532C2V48 SS B1622Q 250 kcmil Stranded 48"
B532C3Q48 SS B1622Q 500 kcmil Stranded 48"
B532D1L48 SS B1642Q #4 Stranded 48"
B532D1V36 SS B1642Q #2 Stranded 36"
B532D2C24 SS B1642Q 1/0 Stranded 24"
B532D2C36 SS B1642Q 1/0 Stranded 36"
B532D2G12 SS B1642Q 2/0 Stranded 12"
B532D2G48 SS B1642Q 2/0 Stranded 48"
B532D2Q36 SS B1642Q 4/0 Stranded 36"
B532D2Q40 SS B1642Q 4/0 Stranded 40"
B532D2Q48 SS B1642Q 4/0 Stranded 48"
B532D2Q50 SS B1642Q 4/0 Stranded 50"
B532D2Q72 SS B1642Q 4/0 Stranded 72"
B532E3D96 SS B1643Q 350 kcmil Stranded 96"
B532E3Q48 SS B1643Q 500 kcmil Stranded 48"
B532E3Q96 SS B1643Q 500 kcmil Stranded 96"
B533A2G48 TA B1612Q 2/0 Stranded 48"
B533A2Q24 TA B1612Q 4/0 Stranded 24"
B533C2Q48 TA B1622Q 4/0 Stranded 48"
B533D2Q12 TA B1642Q 4/0 Stranded 12"
B533D2Q24 TA B1642Q 4/0 Stranded 24"
B533D2Q48 TA B1642Q 4/0 Stranded 48"
Custom lengths available.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.