ERICO CADWELD EXOLON, Cable to Lug or Busbar

Developed in 1988, ERICO CADWELD EXOLON connections represented a significant advancement in welded electrical connections for sensitive indoor applications like data centers, hospitals, and other clean room environments. The virtual elimination of smoke and a unique electronic starting system makes this an ideal solution for sensitive applications. Each ERICO CADWELD EXOLON package contains ceramic filters that produce an extremely low emission connection.

Features

  • Forms a permanent, low resistance connection
  • Provides a molecular bond
  • ERICO CADWELD Exothermic Connections are rated with the same current capacity as the conductor
  • Portable installation equipment with no external source of power required
  • Installers can be easily trained to make ERICO CADWELD Exothermic Connections
  • Connections can be visually inspected
  • Mold Families LA and LE can be used with straight or offset lugs

Specifications

XL-XX-X-XX-XX-L-M-W
XL ERICO CADWELD EXOLON Designation
XX Mold Famliy
X Price Key
XX Lug/Busbar Size
XX Conductor Size
L* Splt Crucible Crucible section is split on molds designed with horizontal opening for easier cleaning
M* Mold Only
W* Wear Plates Reduce mechanical abrasion of molds at cable entry points
* Empty if none

Search

The search below may not contain all product options. For made-to-order configurations, consult the chart above.

Mold Family
Lug/Busbar Size
Conductor Size

Mold Family

Part Number Mold Family Lug/Busbar Size Conductor Size Conductor Outer Diameter, Nominal Certifications
XLGLCCE1L GL 1/8" x 1" #4 Concentric 0.232" cULus
XLGLCCE2C GL 1/8" x 1" 1/0 Concentric 0.373" cULus
XLGLCCE2G GL 1/8" x 1" 2/0 Concentric 0.418" cULus
XLGLCDE2Q GL 3/16" x 1" 4/0 Concentric 0.528" cULus
XLLAP1HAA LA 1/16" x 1/2" #6 Concentric 0.184" cULus
XLLAP1HAAM LA 1/16" x 1/2" #6 Concentric 0.184" cULus
XLLAD5AJH LA 1/2" x 2" 1000 kcmil Ropelay 1.330"
XLLAD5AJHS LA 1/2" x 2" 1000 kcmil Ropelay 1.330"
XLLAC3QEG LA 1/4" x 1 1/2" 500 kcmil Concentric 0.813"
XLLAC1VCE LA 1/8" x 1" #2 Concentric 0.292" cULus
XLLAC1TCE LA 1/8" x 1" #2 Solid 0.257" cULus
XLLAC2GCE LA 1/8" x 1" 2/0 Concentric 0.418" cULus
XLLAC2SCE LA 1/8" x 1" 4/0 Ropelay 0.610" cULus
XLLAC2GDE LA 3/16" x 1" 2/0 Concentric 0.418" cULus
XLLAD2WGHS LA 3/8" x 2" 250 kcmil Ropelay 0.750"
XLLJCAG1V LJ 1/16" x 1 1/2" and wider #2 Concentric 0.292" cULus
XLLJCEG1H LJ 1/4" x 1 1/2" and wider #6 Concentric 0.184" cULus
XLLJCEG1V LJ 1/4" x 1 1/2" and wider #2 Concentric 0.292" cULus
XLLJCEG1T LJ 1/4" x 1 1/2" and wider #2 Solid 0.257" cULus
XLLJCEG2C LJ 1/4" x 1 1/2" and wider 1/0 Concentric 0.373" cULus
XLLJCEG2G LJ 1/4" x 1 1/2" and wider 2/0 Concentric 0.418" cULus
XLLJCEG2L LJ 1/4" x 1 1/2" and wider 3/0 Concentric 0.470" cULus
XLLJCEG2Q LJ 1/4" x 1 1/2" and wider 4/0 Concentric 0.528" cULus
XLLJCEG3Q LJ 1/4" x 1 1/2" and wider 500 kcmil Concentric 0.813"
XLLJCEG3QS LJ 1/4" x 1 1/2" and wider 500 kcmil Concentric 0.813"
XLLJCCE2Q LJ 1/8" x 1" 4/0 Concentric 0.528" cULus
XLLJCGG1V LJ 3/8" x 1 1/2" and wider #2 Concentric 0.292" cULus
XLLJCGG4L LJ 3/8" x 1 1/2" and wider 750 kcmil Concentric 0.998"
XLLJCGG4LS LJ 3/8" x 1 1/2" and wider 750 kcmil Concentric 0.998"
XLLQEEH1VS LQ 1/4" x 2" and wider #2 Concentric 0.292" cULus
XLLQJEH2LMS LQ 1/4" x 2" and wider 3/0 Concentric 0.470" cULus
XLLQJEH2LS LQ 1/4" x 2" and wider 3/0 Concentric 0.470" cULus
XLLQJEH2Q LQ 1/4" x 2" and wider 4/0 Concentric 0.528" cULus
XLLQJEH2QMS LQ 1/4" x 2" and wider 4/0 Concentric 0.528" cULus
XLLQJEH2QS LQ 1/4" x 2" and wider 4/0 Concentric 0.528" cULus
XLLQJEH2VS LQ 1/4" x 2" and wider 250 kcmil Concentric 0.575" cULus
XLLQJEH3QS LQ 1/4" x 2" and wider 500 kcmil Concentric 0.813"
XLLQJEH4LS LQ 1/4" x 2" and wider 750 kcmil Concentric 0.998"
XLLQJGH2V LQ 3/8" x 2" and wider 250 kcmil Concentric 0.575" cULus
XLLQJGH4L LQ 3/8" x 2" and wider 750 kcmil Concentric 0.998"
XLLREEG1T LR 1/4" x 1 1/2" and wider #2 Solid 0.257"
A gap between conductors may be required. See mold tag for more information.