Ground Rod to Lug or Busbar

ERICO CADWELD graphite molds are designed and engineered for thousands of connection styles and conductor combinations.

Features

  • Forms a permanent, low resistance connection
  • Provides a molecular bond
  • ERICO CADWELD Exothermic Connections are rated with the same current capacity as the conductor
  • Portable installation equipment with no external source of power required
  • Installers can be easily trained to make ERICO CADWELD Exothermic Connections
  • Connections can be visually inspected
  • Mold Families LA and LE can be used with straight or offset lugs

Specifications

XX-X-XX-XX-L-M-W
XX Mold Family
X Price Key
XX Ground Rod Code
XX Lug/Busbar Size
L* Split Crucible Crucible section is split on molds designed with horizontal opening for easier cleaning
M* Mold Only
W* Wear Plates Reduce mechanical abrasion of molds at cable entry points
* Empty if none

Search

The search below may not contain all product options. For made-to-order configurations, consult the chart above.

Mold Family
Ground Rod Type
Ground Rod Diameter, Nominal
Ground Rod Diameter, Actual
Lug/Busbar Size

Mold Family

Part Number Mold Family Ground Rod Type Ground Rod Diameter, Nominal Ground Rod Diameter, Actual Lug/Busbar Size Certifications
CMC16EH CM Copper-bonded 5/8" 0.563" 1/4" x 2"
CMC16CAJ CM Copper-bonded 5/8" 0.563" 3 mm x 25 mm
CMC16CAM CM Copper-bonded 5/8" 0.563" 3 mm x 50 mm
CMC16EAJ CM Copper-bonded 5/8" 0.563" 4 mm x 25 mm
CMC16PAJ CM Copper-bonded 5/8" 0.563" 6 mm x 25 mm
CMC16PAL CM Copper-bonded 5/8" 0.563" 6 mm x 40 mm
CMC16PAM CM Copper-bonded 5/8" 0.563" 6 mm x 50 mm
CMC18CAJ CM Copper-bonded 3/4" 0.682" 3 mm x 25 mm
CMC18CAL CM Copper-bonded 3/4" 0.682" 3 mm x 40 mm
CMC22CAJ CM Copper-bonded 1" 0.914" 3 mm x 25 mm
CMD22FAM CM Copper-bonded 1" 0.914" 5 mm x 50 mm
CMC14EAJ CM Steel 1/2" 0.505" 4 mm x 25 mm
CMC14EAL CM Steel 1/2" 0.505" 4 mm x 40 mm
CMC14EAM CM Steel 1/2" 0.505" 4 mm x 50 mm
CMC14FAM CM Steel 1/2" 0.505" 5 mm x 50 mm
CMCP160CAJ CM Steel 16 mm 0.630" 3 mm x 25 mm
CMCP200CAJ CM Steel 20 mm 0.787" 3 mm x 25 mm
CNC16CAJ CN Copper-bonded 5/8" 0.563" 3 mm x 25 mm
CNC16CAK CN Copper-bonded 5/8" 0.563" 3 mm x 30 mm
CNC16EAM CN Copper-bonded 5/8" 0.563" 4 mm x 50 mm
CNC16FAL CN Copper-bonded 5/8" 0.563" 5 mm x 40 mm
CNC18CAJ CN Copper-bonded 3/4" 0.682" 3 mm x 25 mm
CNC18CAK CN Copper-bonded 3/4" 0.682" 3 mm x 30 mm
CNC18CAL CN Copper-bonded 3/4" 0.682" 3 mm x 40 mm
CNC18EAL CN Copper-bonded 3/4" 0.682" 4 mm x 40 mm
CNC14EAJ CN Steel 1/2" 0.505" 4 mm x 25 mm
CNC14EAM CN Steel 1/2" 0.505" 4 mm x 50 mm
CNCP180FAM CN Steel 18 mm 0.710" 5 mm x 50 mm
CNCP200CAK CN Steel 20 mm 0.787" 3 mm x 30 mm
CPC16BAH CP Copper-bonded 5/8" 0.563" 2 mm x 20 mm
CPC16CAJ CP Copper-bonded 5/8" 0.563" 3 mm x 25 mm and wider
CPC16EAJ CP Copper-bonded 5/8" 0.563" 4 mm x 25 mm and wider
CPC18CAJ CP Copper-bonded 3/4" 0.682" 3 mm x 25 mm and wider
CPC18EAJ CP Copper-bonded 3/4" 0.682" 4 mm x 25 mm and wider
CQR16CAH CQ Copper-bonded 5/8" 0.563" 3 mm x 20 mm
CQRP190CAJ CQ Steel 19 mm 0.748" 3 mm x 25 mm
CQRP200PAJ CQ Steel 20 mm 0.787" 6 mm x 25 mm
CQFP200FAN CQ Steel 20 mm 0.787" 5 mm x 60 mm
CRC16EK CR Copper-bonded 5/8" 0.563" 1/4" x 3" and wider
CRC16CE CR Copper-bonded 5/8" 0.563" 1/8" x 1"
CRC16FAM CR Copper-bonded 5/8" 0.563" 5 mm x 50 mm and wider
CRC16PAM CR Copper-bonded 5/8" 0.563" 6 mm x 50 mm and wider
CRC18EH CR Copper-bonded 3/4" 0.682" 1/4" x 2" and wider
CRD18EK CR Copper-bonded 3/4" 0.682" 1/4" x 3" and wider
CRC18EAL CR Copper-bonded 3/4" 0.682" 4 mm x 40 mm and wider
CRC18BAL CR Copper-bonded 3/4" 0.682" 2 mm x 40 mm and wider cULus
CRCP160CAJ CR Steel 16 mm 0.630" 3 mm x 25 mm
CSE16EAJ CS Copper-bonded 5/8" 0.563" 4 mm x 25 mm
CSE16EAM CS Copper-bonded 5/8" 0.563" 4 mm x 50 mm
CSE14EG CS Steel 1/2" 0.505" 1/4" x 1 1/2"
LAC18EK LA (To Ground Rod) Copper-bonded 3/4" 0.682" 1/4" x 3" and wider
For applications such as computer room, tunnel or other low-ventilation areas, specify a smokeless ERICO CADWELD EXOLON mold. Add an XL prefix to the standard mold part number when ordering (for example, a TAC2Q2Q becomes XLTAC2Q2Q). Similarly, ERICO CADWELD EXOLON welding material is also designated by the XL prefix (for example, 150 becomes XL150).
A gap between conductors may be required. See mold tag for more information.