United StatesChange
nVent ERIFLEX

nVent ERIFLEX Flexibar Advanced, Tinned Copper

After extensive research, nVent ERIFLEX is proud to establish a new gold standard in terms of insulation for flexible busbar called nVent ERIFLEX Flexibar Advanced. The new product is low smoke, halogen-free and flame retardant all while maintaining the level of flexibility and reliability that our partners have come to expect from nVent ERIFLEX Flexibar. Compared to standard PVC insulation, nVent ERIFLEX Flexibar Advanced does not generate corrosive gases and produces a relatively low smoke opacity in accordance with ISO 5659-2. The low smoke characteristic improves the visibility conditions for people to be able to easily locate the emergency exit and also allows rescue workers to assess an emergency situation more clearly. nVent ERIFLEX Flexibar Advanced means greater safety for individuals, less damage for your electrical equipment and less environmental impact. The halogen–free feature enables a reduction in the quantity of toxic smoke. nVent ERIFLEX Flexibar Advanced does not contain any halogens, according to IEC 60754-1, minimizing toxicity and making it the ideal product for use in enclosed spaces such as data centers, rail and other spaces where people are welcome such as hospitals and schools. This also facilitates the use of nVent ERIFLEX Flexibar Advanced in specific applications such as submarines, switchboards and other enclosed environments that require a low emissions solution. In addition to being halogen-free, nVent ERIFLEX Flexibar Advanced is also compliant with the UL 94-V0 testing standard. The flame retardant portion of the test illustrates the self-extinguish feature. This superior feature of nVent ERIFLEX Flexibar Advanced is also shown by the Limiting Oxygen Index (LOI) at 30%. In case of fire, ERFILEX Flexibar Advanced generates a limited quantity of smoke that is less damaging to your electrical equipment.

Features

  • Thin layers of tinned electrolytic copper formed into a stack
  • Full range from 19.5 mm² up to 1200 mm² and 125 A to 2800 A
  • Insulated by high-resistance, halogen free, flame retardant and low smoke material with less than 20% contact with conductor for high flexibility
  • Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint
  • Dramatically smaller and more flexible than comparable cable based on ampacity
  • Better power density than cable with lower skin effect ratio
  • Connections made by punching and bolting directly through the copper laminates or clamping onto the end of the nVent ERIFLEX Flexibar
  • No lugs needed, reducing installation time and improving resistance to vibration
  • Weight savings and material savings compared to wire alternatives
  • Reduces total installation cost
  • Traceability codes and designation part numbers printed on insulation
  • Conforms to NF EN 45545 obtaining an HL2 classification for chapters R22 and R23
  • 100% production dielectric tested
  • RoHS compliant

Specifications

Typical Application Current Rating
Finish: Tinned
Material: Copper; Thermoplastic Elastomer
Dielectric Strength: 20 kV/mm
Flammability Rating: UL® 94V-0
Halogen Free Rating: UL® 2885; IEC® 60754-1; IEC® 62821-1
Low Smoke Rating: IEC® 61034-2; ISO 5659-2; UL® 2885
Smoke, Toxicity and Acidity Rating: IEC® 60754-2
Insulation Elongation: 500 %
Insulation Thickness: 0.07"
Nominal Voltage, UL/CSA/IEC: 1,000 VAC; 1,500 VDC
Working Temperature: -58 to 239 °F
Complies With: IEC® 60695-2-11 (Glow Wire Test 960 °C); IEC® 61439.1; IEC® 61439.1 Class II
Typical Application Current Rating: 125 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC3X9 534001 6.56 126 158 185 3 0.354 0.031 42.64 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC3X13 534004 6.56 128 160 187 3 0.512 0.020 38.49 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X6 534000 6.56 131 164 192 8 0.236 0.020 47.38 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC2X15-5 534006 6.56 152 190 222 2 0.610 0.031 48.96 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X9 534002 6.56 192 241 281 6 0.354 0.031 85.28 1.72 2.25 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 250 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC6X13 534005 6.56 188 235 275 6 0.512 0.020 76.99 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC2X20X1 534010 6.56 211 263 307 2 0.787 0.039 78.96 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X15-5 534007 6.56 223 279 326 4 0.610 0.031 97.91 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC2X24X1 534016 6.56 244 305 357 2 0.945 0.039 94.75 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC9X9 534003 6.56 251 314 366 9 0.354 0.031 127.92 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC3X20X1 534011 6.56 263 328 383 3 0.787 0.039 118.44 1.72 2.25 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 400 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC6X15-5 534008 6.56 282 353 412 6 0.610 0.031 146.87 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC3X24X1 534017 6.56 304 379 443 3 0.945 0.039 142.13 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X20X1 534012 6.56 308 385 450 4 0.787 0.039 157.92 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC2X32X1 534023 6.56 311 388 454 2 1.260 0.039 126.34 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC5X20X1 534013 6.56 351 438 512 5 0.787 0.039 197.40 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X24X1 534018 6.56 356 445 520 4 0.945 0.039 189.50 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC2X40X1 534030 6.56 376 470 549 2 1.575 0.039 157.92 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC3X32X1 534024 6.56 385 481 562 3 1.260 0.039 189.50 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC10X15-5 534009 6.56 387 483 565 10 0.610 0.031 244.78 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X20X1 534014 6.56 390 487 569 6 0.787 0.039 236.88 1.72 2.25 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 500 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC5X24X1 534019 6.56 403 504 589 5 0.945 0.039 236.88 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X24X1 534020 6.56 448 559 653 6 0.945 0.039 284.26 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X32X1 534025 6.56 449 561 655 4 1.260 0.039 252.67 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC3X40X1 534031 6.56 464 580 677 3 1.575 0.039 236.88 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X40X1 534032 6.56 541 675 789 4 1.575 0.039 315.84 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC3X50X1 534037 6.56 562 702 820 3 1.969 0.039 300.00 1.72 2.25 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 630 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC5X32X1 534026 6.56 507 633 740 5 1.260 0.039 315.84 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X24X1 534021 6.56 531 663 775 8 0.945 0.039 379.01 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC10X20X1 534015 6.56 532 661 777 10 0.787 0.039 394.80 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X32X1 534027 6.56 561 701 819 6 1.260 0.039 379.01 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC5X40X1 534033 6.56 608 759 887 5 1.575 0.039 394.80 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X50X1 534038 6.56 651 813 950 4 1.969 0.039 394.80 1.72 2.25 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 800 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC10X24X1 534022 6.56 606 757 885 10 0.945 0.039 473.76 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X32X1 534028 6.56 657 821 959 8 1.260 0.039 505.34 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X40X1 534034 6.56 669 835 976 6 1.575 0.039 473.76 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC5X50X1 534039 6.56 730 911 1,065 5 1.969 0.039 493.50 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X63X1 534044 6.56 792 988 1,155 4 2.480 0.039 497.45 1.65 2.12 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 1,000 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC10X32X1 534029 6.56 745 931 1,088 10 1.260 0.039 631.68 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X40X1 534035 6.56 786 981 1,146 8 1.575 0.039 631.68 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X50X1 534040 6.56 802 1,002 1,171 6 1.969 0.039 592.20 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC10X40X1 534036 6.56 879 1,097 1,282 10 1.575 0.039 789.60 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC5X63X1 534045 6.56 883 1,102 1,288 5 2.480 0.039 621.81 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X50X1 534041 6.56 927 1,157 1,352 8 1.969 0.039 789.60 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X63X1 534046 6.56 966 1,205 1,408 6 2.480 0.039 746.17 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC4X80X1 534049 6.56 970 1,211 1,415 4 3.150 0.039 631.68 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC5X80X1 534050 6.56 1,077 1,344 1,570 5 3.150 0.039 789.60 1.65 2.12 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 1,250 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC10X50X1 534042 6.56 1,040 1,298 1,517 10 1.969 0.039 987.00 1.72 2.25 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X63X1 534047 6.56 1,108 1,383 1,616 8 2.480 0.039 994.90 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X80X1 534051 6.56 1,172 1,463 1,709 6 3.150 0.039 947.52 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC5X100X1 534055 6.56 1,301 1,624 1,898 5 3.937 0.039 987.00 1.60 2.02 CE, CSA, cURus, EAC, RoHS
FADV2MTC6X100X1 534056 6.56 1,414 1,765 2,062 6 3.937 0.039 1,184.40 1.60 2.02 CE, CSA, cURus, EAC, RoHS
Typical Application Current Rating: 1,600 A
Certification Details: UL® 67
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC12X100 534059 6.56 1,920 2,396 2,800 12 3.937 0.039 2,368.80 1.60 2.02 CE, CSA, cURus, EAC, RoHS
FADV2MTC10X120 534060 6.56 2,049 2,555 2,987 10 4.724 0.039 2,368.80 1.49 1.95 CE, CSA, cUR, EAC
Typical Application Current Rating: 1,600 A
Certification Details: UL® 67; UL® 758
Part Number Article Number L(') ∆T 30 K(A) ∆T 45 K(A) ∆T 60 K(A) N A(") B(") Cross Section(kcmil) 2 Bar Current Coefficient 3 Bar Current Coefficient Certifications
FADV2MTC10X63X1 534048 6.56 1,232 1,538 1,797 10 2.480 0.039 1,243.62 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X80X1 534052 6.56 1,341 1,674 1,956 8 3.150 0.039 1,263.36 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC10X80X1 534053 6.56 1,484 1,851 2,164 10 3.150 0.039 1,579.20 1.65 2.12 CE, CSA, cURus, EAC, RoHS
FADV2MTC8X100X1 534057 6.56 1,598 1,994 2,330 8 3.937 0.039 1,579.20 1.60 2.02 CE, CSA, cURus, EAC, RoHS
FADV2MTC10X100 534058 6.56 1,765 2,203 2,574 10 3.937 0.039 1,974.00 1.60 2.02 CE, CSA, cURus, EAC, RoHS
ADMISSIBLE CURRENTS: This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear.
∆T = Temperature of conductors – Internal temperature of panel.
Refer to technical documentation for additional ampacity ratings.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

CSA, CSA-US and C-CSA-US are registered trademarks of Canadian Standards Association.
IEC is a registered trademark of the International Electrotechnical Commission.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Video

Brochures

Catalogs

FLEXIBLE CONDUCTORS
35.74 MB English

Certifications

CSA 90005
CSA C22.2 No. 0, CSA C22.2 No. 210
cUR AVLV8.E316390
CSA C22.2 No. 210
cUR QEUY8.E125470
CSA C22.2 No. 29, CSA C22.2 No. 244
EAC 02941 (Russian Federation)
3.56 MB Русско
EN 45545-2 CC11618_FADV_IBSADV
EN 45545-2, 117 KB English
IEC 60695-2-12 CC10817_FADV
IEC 60695-2-12, 49 KB English
IEC 60754-1-2 CC10917_FADV
IEC 60754-1-2, 49 KB English
IEC 61439-1 Class II FLEXIBAR_ADV
IEC 61439-1 Class II, 28 KB English
IEC 61439-1 FLEXIBAR_ADV
IEC 61439-1, 50 KB English
ISO 5659-2 CC11117_FADV
ISO 5659-2, 119 KB English
UR QEUY2.E125470
ANSI/UL 67, ANSI/UL 891

Engineering Specifications

Success Stories

Technical