United StatesChange
LENTON

A2 Standard Coupler, Plain

Features

  • Designed to splice the same diameter bars where the second bar can be rotated and is not restricted in its axial direction
  • Slim design maintains concrete cover
  • Installs quickly and easily

Specifications

Material: Steel
Finish: Plain
100% U.S. Domestic Content: Yes
Coupler Protector: Standard
Part Number Rebar Size, Metric Rebar Size, US Rebar Size, Canada Hex WidthW DiameterØ LengthL Bar DepthBD Bar GapBG Unit Weight
EL12A2 12 mm #4 10M 0.69" 1.63" 0.58" 0.47" 0.1 lb
EL16A2 16 mm #5 15M 0.88" 2.19" 0.86" 0.47" 0.3 lb
EL20A2 20 mm #6 20M 1.06" 2.81" 1.09" 0.63" 0.5 lb
EL22A2 22 mm #7 1.19" 3.16" 1.26" 0.64" 0.7 lb
EL25A2 25 mm #8 25M 1.38" 3.34" 1.36" 0.62" 0.9 lb
EL28A2 28 mm #9 30M 1.50" 3.59" 1.49" 0.61" 1.0 lb
EL32A2 32 mm #10 1.75" 3.78" 1.58" 0.62" 1.5 lb
EL36A2 36 mm #11 35M 1.88" 3.97" 1.68" 0.61" 1.8 lb
EL38A2 38 mm #12 2.00" 4.13" 1.75" 0.63" 2.1 lb
EL40A2 40 mm 2.25" 5.00" 2.17" 0.66" 3.4 lb
EL43TA2 43 mm #14 45M 2.25" 5.25" 2.20" 0.85" 3.4 lb
EL50TA2 50 mm 2.75" 6.41" 2.78" 0.85" 6.2 lb
EL57TA2 57 mm #18 55M 3.00" 6.47" 2.81" 0.85" 7.3 lb
Coupler Protector: Tapered Plastic Screw-In Plug (ELCP)
Part Number Rebar Size, Metric Rebar Size, US Rebar Size, Canada Hex WidthW DiameterØ LengthL Bar DepthBD Bar GapBG Unit Weight
EL12A2WCP 12 mm #4 10M 0.69" 1.63" 0.58" 0.47" 0.1 lb
EL16A2WCP 16 mm #5 15M 0.88" 2.19" 0.86" 0.47" 0.3 lb
EL20A2WCP 20 mm #6 20M 1.06" 2.81" 1.09" 0.63" 0.5 lb
Coupler Protector: Internal Plastic Form Saver Plug (ELICP)
Part Number Rebar Size, Metric Rebar Size, US Rebar Size, Canada Hex WidthW DiameterØ LengthL Bar DepthBD Bar GapBG Unit Weight
EL36A2WICP 36 mm #11 35M 1.88" 3.97" 1.68" 0.61" 1.8 lb
Coupler Protector: None
Part Number Rebar Size, Metric Rebar Size, US Rebar Size, Canada Hex WidthW DiameterØ LengthL Bar DepthBD Bar GapBG Unit Weight
EL16A2LCP 16 mm #5 15M 0.88" 2.19" 0.86" 0.47" 0.3 lb
Designed to Meet
AASHTO, ABNT NBR 8548:1984, ACI 318 Type 1 (125% Specified Yield), ACI 318 Type 2 (Specified Ultimate), ACI 349, ACI 359, AS3600, CAN/CSA - N287.2/.3/.4, IBC Type 1 (125% Specified Yield), IBC Type 2 (Specified Ultimate), US Army Corps of Engineers
Bar dimensions and weights listed may vary by region. Coupler sizes not shown may be available by special order. Contact your LENTON representative for more information.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.