United StatesChange
ERICO

Non-Insulated Stranded Conductor for Lightning Protection

Features

  • Provides a path to ground for lightning currents

Specifications

Certification Details: UL® 96
Material: Aluminum
Part Number UL Conductor Class Conductor Type Number of Wires Wire Diameter(") Ø(") L(') Cross Section(kcmil) Unit Weight(lb) Certifications
LPA100250 Class I Smooth Weave 24 0.064 0.480 250 98.64 0.102 cULus
LPA100500 Class I Smooth Weave 24 0.064 0.480 500 98.64 0.102 cULus
LPA100CTO Class I Smooth Weave 24 0.064 0.480 98.64 0.102 cULus
LPA101500 Class I Smooth Weave 26 0.064 0.520 500 106.68 0.109 UL
LPA101CTO Class I Smooth Weave 26 0.064 0.520 106.68 0.109 UL
LPA102500 Class I Smooth Weave 28 0.064 0.550 500 115.08 0.115 UL
LPA102CTO Class I Smooth Weave 28 0.064 0.550 115.08 0.115 UL
LPA105250 Class II Concentric 37 0.076 0.550 250 211.00 0.204 UL
LPA105500 Class II Concentric 37 0.076 0.550 500 211.00 0.204 UL
LPA105CTO Class II Concentric 37 0.076 0.550 211.00 0.204 UL
LPA140500 Secondary Smooth Weave 10 0.064 0.350 500 41.10 0.040 UL
LPA140CTO Secondary Smooth Weave 10 0.064 0.350 41.10 0.040 UL
Material: Copper
Part Number UL Conductor Class Conductor Type Number of Wires Wire Diameter(") Ø(") L(') Cross Section(kcmil) Unit Weight(lb) Certifications
LPC120250 Class I Smooth Weave 29 0.045 0.440 250 59.45 0.192 UL
LPC120500 Class I Smooth Weave 29 0.045 0.440 500 59.45 0.192 UL
LPC120CTO Class I Smooth Weave 29 0.045 0.440 59.45 0.192 UL
LPC122250 Class I Smooth Weave 32 0.045 0.480 250 65.60 0.220 UL
LPC122500 Class I Smooth Weave 32 0.045 0.480 500 65.60 0.220 UL
LPC122CTO Class I Smooth Weave 32 0.045 0.480 65.60 0.220 UL
LPC123250 Class I Smooth Weave 36 0.045 0.500 250 73.80 0.240 UL
LPC123500 Class I Smooth Weave 36 0.045 0.500 500 73.80 0.240 UL
LPC123CTO Class I Smooth Weave 36 0.045 0.500 73.80 0.240 UL
LPC124250 Class I Smooth Weave 40 0.045 0.530 250 82.00 0.270 UL
LPC124500 Class I Smooth Weave 40 0.045 0.530 500 82.00 0.270 UL
LPC124CTO Class I Smooth Weave 40 0.045 0.530 82.00 0.270 UL
LPC125250 Class I Ropelay 24 0.064 0.450 250 98.64 0.340 UL
LPC125CTO Class I Ropelay 24 0.064 0.450 98.64 0.340 UL
LPC126R250 Class II Ropelay 28 0.064 0.470 250 115.08 0.380 UL
LPC126R500 Class II Ropelay 28 0.064 0.470 500 115.08 0.380 UL
LPC126RCTO Class II Ropelay 28 0.064 0.470 115.08 0.380 UL
LPC127250 Class II Ropelay 32 0.064 0.530 250 131.52 0.440 UL
LPC127500 Class II Ropelay 32 0.064 0.530 500 131.52 0.440 UL
LPC127CTO Class II Ropelay 32 0.064 0.530 131.52 0.440 UL
LPC128250 Class I Smooth Weave 24 0.064 0.550 250 98.64 0.340 cULus
LPC128500 Class I Smooth Weave 24 0.064 0.550 500 98.64 0.340 cULus
LPC128CTO Class I Smooth Weave 24 0.064 0.550 98.64 0.340 cULus
LPC134250 Class II Concentric 19 0.084 0.500 250 133.12 0.411 UL
LPC136500 Class II Concentric 37 0.068 0.600 500 167.80 0.520 UL
LPC136CTO Class II Concentric 37 0.068 0.600 167.80 0.520 UL
LPC137250 Class II Concentric 37 0.076 0.650 250 211.60 0.653 UL
LPC137CTO Class II Concentric 37 0.076 0.650 211.60 0.653 UL
LPC137LCTO Class II Concentric 37 0.076 0.650 211.60 0.653 UL
LPC150500 Secondary Smooth Weave 14 0.045 0.250 500 28.70 0.092 UL
LPC150CTO Secondary Smooth Weave 14 0.045 0.250 28.70 0.092 UL
LPC401CTO Class II Ropelay 28 0.064 0.470 115.08 0.380 UL
LPC404CTO Class II Concentric 19 0.106 0.650 211.60 0.653 UL
Material: Copper
Finish: Lead Covered
Part Number UL Conductor Class Conductor Type Number of Wires Wire Diameter(") Ø(") L(') Cross Section(kcmil) Unit Weight(lb) Certifications
LPLC401CTO Class II Concentric 19 0.084 0.570 115.08 1.380 UL
LPLC404CTO Class II Concentric 19 0.106 0.653 211.60 1.983 UL
Material: Copper
Finish: Tinned
Part Number UL Conductor Class Conductor Type Number of Wires Wire Diameter(") Ø(") L(') Cross Section(kcmil) Unit Weight(lb) Certifications
LPC120L250 Class I Smooth Weave 29 0.045 0.440 250 59.45 0.192 UL
LPC120L500 Class I Smooth Weave 29 0.045 0.440 500 59.45 0.192 UL
LPC120LCTO Class I Smooth Weave 29 0.045 0.440 59.45 0.192 UL
LPC122L250 Class I Smooth Weave 32 0.045 0.480 250 65.60 0.220 UL
LPC122L500 Class I Smooth Weave 32 0.045 0.480 500 65.60 0.220 UL
LPC122LCTO Class I Smooth Weave 32 0.045 0.480 65.60 0.220 UL
LPC124L500 Class I Smooth Weave 40 0.045 0.530 500 82.00 0.270 UL
LPC124LCTO Class I Smooth Weave 40 0.045 0.530 82.00 0.270 UL
LPC126RL250 Class II Ropelay 28 0.064 0.470 250 115.08 0.380 UL
LPC126RL500 Class II Ropelay 28 0.064 0.470 500 115.08 0.380 UL
LPC126RLCTO Class II Ropelay 28 0.064 0.470 115.08 0.380 UL
LPC127L250 Class II Ropelay 32 0.064 0.530 250 131.52 0.440 UL
LPC127LCTO Class II Smooth Weave 32 0.064 0.530 131.52 0.440 UL
LPC137L250 Class II Concentric 37 0.076 0.650 250 211.60 0.653 UL
Equivalent Conductor Size
Part Number Conductor Size
LPC134xxx 2/0
LPC136xxx 3/0
LPC137xxx 4/0
Unit weight is per foot (0.3048 m).
Cut-to-order (CTO) lengths are available for an additional charge.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.