United StatesChange
CADDY

PH Multi-Purpose Purlin Clamp

Features

  • Attaches to bottom of purlins and beams to support threaded rod

Specifications

Material: Steel
Finish: Electrogalvanized
Part Number Rod SizeRS Flange ThicknessFT B TorqueTQ Static Load 1F1 Static Load 2F2 Nut Included
PH4 1/4" 1/4" Max 3/4" Min 30 in lb 200 lb 160 lb No
PH6 3/8" 1/4" Max 3/4" Min 30 in lb 200 lb 160 lb No
PH6FP 3/8" 1/4" Max 3/4" Min 30 in lb 200 lb Yes
A jam nut is required for fire protection applications.
Refer to Static Load 1 when attaching to C and Z purlins. Refer to Static Load 2 when attaching to a flat flange.
Recognizing that torque wrenches are generally not used or available on many job sites, the setscrew should be tightened so it contacts the I-beam and then an additional 1/4 to 1/2 turn added.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications