United StatesChange
CADDY

Bolt Close Conduit/Pipe Clamp

Features

  • Retained bolt and built-in nut means there are less parts to handle or drop
  • Combo head bolt works with slotted, hex, #3 phillips or #2 robertson drivers

Specifications

Material: Steel
Finish: Electrogalvanized
Nut Type: Built-In Nut
Part Number Outer DiameterOD EMT Conduit Size Rigid Conduit/Pipe Size Hole SizeHS Static Load 1F1 Static Load 2F2 Certifications Standard Packaging Quantity
CD0B 0.670" – 0.840" 1/2" 1/2" 1/4" 200 lb 50 lb cULus 100 pc
CD0BBP 0.670" – 0.840" 1/2" 1/2" 1/4" 200 lb 50 lb cULus 1 pc
CD0B37 0.670" – 0.840" 1/2" 1/2" 3/8" 200 lb 50 lb 100 pc
CD1B 0.740" – 1.050" 3/4" 3/4" 1/4" 200 lb 50 lb cULus 100 pc
CD1B37 0.740" – 1.050" 3/4" 3/4" 3/8" 200 lb 50 lb 100 pc
CD2B 1.000" – 1.315" 1" 1" 1/4" 200 lb 50 lb cULus 100 pc
CD2B37 1.000" – 1.315" 1" 1" 3/8" 200 lb 50 lb 100 pc
CD2.5B 1.220" – 1.510" 1 1/4" 1/4" 200 lb 50 lb cULus 100 pc
CD2.5B37 1.220" – 1.510" 1 1/4" 3/8" 200 lb 50 lb 100 pc
CD3B 1.410" – 1.740" 1 1/2" 1 1/4" 1/4" 200 lb 50 lb cULus 100 pc
CD3B37 1.410" – 1.740" 1 1/2" 1 1/4" 3/8" 200 lb 50 lb 100 pc
CD4B 1.750" – 1.900" 1 1/2" 5/16" 200 lb 50 lb cULus 50 pc
CD4B37 1.750" – 1.900" 1 1/2" 3/8" 200 lb 50 lb 50 pc
CD5B 1.910" – 2.875" 2" 2" 5/16" 200 lb 50 lb cULus 50 pc
CD5B37 1.910" – 2.875" 2" 2" 3/8" 200 lb 50 lb 50 pc
Material: Steel
Finish: Electrogalvanized
Nut Type: Hex Nut
Part Number Outer DiameterOD EMT Conduit Size Rigid Conduit/Pipe Size Hole SizeHS Static Load 1F1 Static Load 2F2 Certifications Standard Packaging Quantity
CD6B 2.600" – 3.000" 2 1/2" 2 1/2" 5/16" 350 lb 50 lb 25 pc
CD7B 3.150" – 3.500" 3" 3" 5/16" 350 lb 50 lb 25 pc
CD8B 3.740" – 4.130" 3 1/2" 3 1/2" 5/16" 350 lb 50 lb 10 pc
CD9B 4.250" – 4.530" 4" 4" 5/16" 350 lb 50 lb 10 pc
Material: Stainless Steel 302 (EN 1.4324)
Nut Type: Hex Nut
Part Number Outer DiameterOD EMT Conduit Size Rigid Conduit/Pipe Size Hole SizeHS Static Load 1F1 Static Load 2F2 Certifications Standard Packaging Quantity
CD0BSS 0.670" – 0.840" 1/2" 1/2" 1/4" 200 lb 50 lb cULus 100 pc
CD1BSS 0.740" – 1.050" 3/4" 3/4" 1/4" 200 lb 50 lb cULus 100 pc
CD2BSS 1.000" – 1.315" 1" 1" 1/4" 200 lb 50 lb 100 pc
CD2.5BSS 1.220" – 1.510" 1 1/4" 1/4" 200 lb 50 lb cULus 100 pc
CD3BSS 1.410" – 1.740" 1 1/2" 1 1/4" 1/4" 200 lb 50 lb cULus 100 pc
CD4BSS 1.750" – 1.900" 1 1/2" 5/16" 200 lb 50 lb cULus 50 pc
CD5BSS 1.910" – 2.875" 2" 2" 5/16" 350 lb 50 lb cULus 50 pc
CD6BSS 2.600" – 3.000" 2 1/2" 2 1/2" 5/16" 350 lb 50 lb 25 pc
CD7BSS 3.150" – 3.500" 3" 3" 5/16" 350 lb 50 lb 25 pc
CD8BSS 3.740" – 4.130" 3 1/2" 3 1/2" 5/16" 350 lb 50 lb 10 pc
CD9BSS 4.250" – 4.530" 4" 4" 5/16" 350 lb 50 lb 10 pc

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications