After extensive research, nVent ERIFLEX is proud to establish a new gold standard in terms of insulation for flexible busbar called nVent ERIFLEX Flexibar Advanced. The new product is low smoke, halogen-free and flame retardant all while maintaining the level of flexibility and reliability that our partners have come to expect from nVent ERIFLEX Flexibar. Compared to standard PVC insulation, nVent ERIFLEX Flexibar Advanced does not generate corrosive gases and produces a relatively low smoke opacity in accordance with ISO 5659-2. The low smoke characteristic improves the visibility conditions for people to be able to easily locate the emergency exit and also allows rescue workers to assess an emergency situation more clearly. nVent ERIFLEX Flexibar Advanced means greater safety for individuals, less damage for your electrical equipment and less environmental impact. The halogen–free feature enables a reduction in the quantity of toxic smoke. nVent ERIFLEX Flexibar Advanced does not contain any halogens, according to IEC 60754-1, minimizing toxicity and making it the ideal product for use in enclosed spaces such as data centers, rail and other spaces where people are welcome such as hospitals and schools. This also facilitates the use of nVent ERIFLEX Flexibar Advanced in specific applications such as submarines, switchboards and other enclosed environments that require a low emissions solution. In addition to being halogen-free, nVent ERIFLEX Flexibar Advanced is also compliant with the UL 94-V0 testing standard. The flame retardant portion of the test illustrates the self-extinguish feature. This superior feature of nVent ERIFLEX Flexibar Advanced is also shown by the Limiting Oxygen Index (LOI) at 30%. In case of fire, ERFILEX Flexibar Advanced generates a limited quantity of smoke that is less damaging to your electrical equipment.

Features

  • Thin layers of tinned electrolytic copper formed into a stack
  • Full range from 19.5 mm² up to 1200 mm² and 125 A to 2800 A
  • Insulated by high-resistance, halogen free, flame retardant and low smoke material with less than 20% contact with conductor for high flexibility
  • Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint
  • Dramatically smaller and more flexible than comparable cable based on ampacity
  • Better power density than cable with lower skin effect ratio
  • Connections made by punching and bolting directly through the copper laminates or clamping onto the end of the nVent ERIFLEX Flexibar
  • No lugs needed, reducing installation time and improving resistance to vibration
  • Weight savings and material savings compared to wire alternatives
  • Reduces total installation cost
  • Traceability codes and designation part numbers printed on insulation
  • Conforms to NF EN 45545 obtaining an HL2 classification for chapters R22 and R23
  • 100% production dielectric tested
  • RoHS compliant

Specifications

Part Number FADV2MTC3X32X1
Article Number 534024
Typical Application Current Rating 400 A
Finish Tinned
Material Copper
Thermoplastic Elastomer
Dielectric Strength 20 kV/mm
Flammability Rating UL® 94V-0
Halogen Free Rating UL® 2885
IEC® 60754-1
IEC® 62821-1
Low Smoke Rating IEC® 61034-2
ISO 5659-2
UL® 2885
Smoke, Toxicity and Acidity Rating IEC® 60754-2
Insulation Elongation 500 %
Insulation Thickness 0.07"
Nominal Voltage, UL/CSA/IEC 1,000 VAC
1,500 VDC
Working Temperature -58 to 239 °F
Certification Details UL® 67
UL® 758
Complies With IEC® 60695-2-11 (Glow Wire Test 960 °C)
IEC® 61439.1
IEC® 61439.1 Class II
Length (L) 6.56'
∆T 30 K 385 A
∆T 45 K 481 A
∆T 60 K 562 A
Conducting Layers (N) 3
A 1.26"
B 0.039"
Cross Section 189.5 kcmil
2 Bar Current Coefficient 1.72
3 Bar Current Coefficient 2.25
Unit Weight 4.85 lb
Certifications CE
CSA 90005
cURus
EAC 02941 (Russian Federation)
EN 45545-2 CC11618_FADV_IBSADV
IEC 60695-2-12 CC10817_FADV
IEC 60754-1-2 CC10917_FADV
IEC 61439-1 Class II FLEXIBAR_ADV
IEC 61439-1 FLEXIBAR_ADV
ISO 5659-2 CC11117_FADV
RoHS
Standard Packaging Quantity 2 pc
UPC 78285693756
EAN-13 0782856937562
ADMISSIBLE CURRENTS: This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear.
∆T = Temperature of conductors – Internal temperature of panel.
Refer to technical documentation for additional ampacity ratings.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

CSA, CSA-US and C-CSA-US are registered trademarks of Canadian Standards Association.
IEC is a registered trademark of the International Electrotechnical Commission.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Video

Brochures

Catalogs

FLEXIBLE CONDUCTORS
9.03 MB English

Certifications

CSA 90005
CSA C22.2 No. 0, CSA C22.2 No. 210
cUR AVLV8.E316390
CSA C22.2 No. 210
cUR QEUY8.E125470
CSA C22.2 No. 29, CSA C22.2 No. 244
EAC 02941 (Russian Federation)
3.56 MB Русско
EN 45545-2 CC11618_FADV_IBSADV
EN 45545-2, 117 KB English
IEC 60695-2-12 CC10817_FADV
IEC 60695-2-12, 49 KB English
IEC 60754-1-2 CC10917_FADV
IEC 60754-1-2, 49 KB English
IEC 61439-1 Class II FLEXIBAR_ADV
IEC 61439-1 Class II, 28 KB English
IEC 61439-1 FLEXIBAR_ADV
IEC 61439-1, 50 KB English
ISO 5659-2 CC11117_FADV
ISO 5659-2, 119 KB English
UR QEUY2.E125470
ANSI/UL 67, ANSI/UL 891

Engineering Specifications

Success Stories

Technical