United StatesChange
ERIFLEX

IBS Round Insulated Braided Conductor

IBS120-830-10 (558274)

IBS Round Insulated Braided Conductors are the ideal ready-to-install flexible wire replacement solution. They connect to the terminals of an electrical device without the need for additional accessories, such as angular connectors, spreaders, ring terminal connectors or extenders. IBS Round Insulated Braided Conductors are available in cross sections of 120, 185 and 240 mm² (236.82, 365.10, and 473.65 kcmil), lengths from 330 to 1,030 mm (9.06" to 40.55"), and amperages ranging from 420 to 630 A.

Manufactured in an ISO 9001 certified facility, IBS Round Insulated Braided Conductors are formed by weaving high-quality electrolytic copper wire to form a durable low voltage connector with maximum flexibility that allows for more compact power connections. The IBS Round Insulated Braided Conductor allows users to reduce the total size and weight of the installation, improving both design flexibility and assembly aesthetics.

The IBS Round Insulated Braided Conductor features pre-punched palms that are ready to connect out of the box. There are no lugs to purchase or install, making connections simpler and faster and eliminating faulty connections due to vibration or fatigue. The insulation is a high-resistance self-extinguishing PVC.

Features

  • Resistant to vibration, improving reliability and performance
  • Improves assembly flexibility and aesthetics
  • Quick and easy installation
  • No additional cutting, stripping, crimping and punching needed
  • Small wire diameter provides maximum flexibility
  • RoHS compliant

Specifications

Part Number IBS120-830-10
Article Number 558274
Finish Tinned
Typical Application Current Rating 400 A
Material Copper
Polyvinylchloride
Dielectric Strength 20 kV/mm
Flammability Rating UL® 94V-0
Max Working Voltage, IEC/UL 758 1,000 VAC
1,500 VDC
Max Working Voltage, UL 67 600 VAC/DC
Working Temperature 221 °F Max
Operating Temperature -58 to 221 °F
Wire Diameter 0.006"
Complies With IEC® 60439.1
IEC® 61439.1
IEC® 61439.1 Class II
Cross Section 236.82 kcmil
Conductor Width 0.94"
Conductor Thickness 0.39"
Length (L) 32.68"
A 0.47"
Diameter (Ø) 1.06"
Hole Size (HS) 0.41"
Unit Weight 2.84 lb
Certifications ABS 13-HS1070074-PDA
CE
CSA 90005
cURus
EAC 0234251 (Russian Federation)
IEC 61439-1 Class II IBS-IBSB-IBSBR
IEC 61439-1 IBS-IBSB-IBSBR
RoHS
Standard Packaging Quantity 2 pc
UPC 78285652107
EAN-13 3479775582740
Maximum Ampacity Ratings
Cross Section (mm²/kcmil) ΔT 30° C (A) ΔT 40° C (A) ΔT 45° C (A) ΔT 50° C (A) ΔT 55° C (A) ΔT 60° C (A) ΔT 70° C (A) 2 Bar Current Coefficient
120/236.82 325 376 398 420 441 460 497 1.6
185/365.10 407 470 499 526 552 576 622 1.6
240/473.65 488 563 598 630 661 690 745 1.6
∆T = Temperature of conductors – Internal temperature of panel.
This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

ABS is a registered certification mark of American Bureau of Shipping.
CSA, CSA-US and C-CSA-US are registered trademarks of Canadian Standards Association.
IEC is a registered trademark of the International Electrotechnical Commission.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Brochures

Catalogs

Flexible Conductors
10.96 MB English

Certifications

CSA 90005
CSA C22.2 No. 0, CSA C22.2 No. 210
cUR QEUY8.E125470
CSA C22.2 No. 29, CSA C22.2 No. 244
IEC 61439-1 Class II IBS-IBSB-IBSBR
IEC 61439-1 (2011), EN 61439-1 (2012), 51 KB English
IEC 61439-1 IBS-IBSB-IBSBR
IEC 61439-1 (2012), 50 KB English
UR AVLV2.E316390
ANSI/UL 758
UR QEUY2.E125470
ANSI/UL 67, ANSI/UL 891

Datasheets