United StatesChange
ERIFLEX

IBS Flat Insulated Braided Conductor

IBS25-330-8-10 (558241)

IBS Flat Insulated Braided Conductors are the ideal ready-to-install flexible wire replacement solution. They connect directly to the front access terminals of an electrical device without the need for additional accessories, such as angular connectors, spreaders, ring terminal connectors or extenders. IBS Flat Insulated Braided Conductors are available in cross section of 25 and 50 mm² (49.34 and 98.68 kcmil), lengths from 230 to 1,030 mm (9.06" to 40.55"), and amperages ranging from 177 to 274 A.

Manufactured in an ISO 9001 certified proprietary automated facility, IBS Flat Insulated Braided Conductors are formed by weaving high-quality electrolytic copper wire to form a durable low voltage connector with maximum flexibility that allows for more compact power to electrical device. The IBS Flat Insulated Braided Conductor allows users to reduce the total size and weight of the installation, improving both design flexibility and assembly aesthetics.

The IBS Flat Insulated Braided Conductor features integral pre-punched palms that are ready to connect out of the box. There are no lugs to purchase or install, making connections simpler and faster and eliminating faulty connections due to vibration or fatigue. The insulation is a high-resistance self-extinguishing PVC.

Features

  • Suitable for all main electrical devices
  • Resistant to vibration, improving reliability and performance
  • Improves assembly flexibility and aesthetics
  • Quick and easy installation
  • No additional cutting, stripping, crimping and punching needed
  • Integral palm without lugs or terminals reduces material and assembly weight
  • Small wire diameter provides maximum flexibility
  • RoHS compliant

Specifications

Part Number IBS25-330-8-10
Article Number 558241
Finish Tinned
Typical Application Current Rating 160 A
Material Copper
Polyvinylchloride
Dielectric Strength 20 kV/mm
Flammability Rating UL® 94V-0
Max Working Voltage, IEC/UL 758 1,000 VAC
1,500 VDC
Max Working Voltage, UL 67 600 VAC/DC
Working Temperature 221 °F Max
Operating Temperature -58 to 221 °F
Wire Diameter 0.006"
Complies With IEC® 60439.1
IEC® 61439.1
IEC® 61439.1 Class II
Cross Section 49.34 kcmil
Conductor Width 0.79"
Conductor Thickness 0.07"
Length (L) 12.99"
A 0.39"
B 0.47"
C 0.98"
D 0.24"
Hole Size 1 (HS1) 0.33"
Hole Size 2 (HS2) 0.41"
Unit Weight 0.31 lb
Certifications ABS 13-HS1070074-PDA
CE
CSA 90005
cURus
EAC 0234251 (Russian Federation)
IEC 61439-1 Class II IBS-IBSB-IBSBR
IEC 61439-1 IBS-IBSB-IBSBR
RoHS
Standard Packaging Quantity 10 pc
UPC 78285652094
EAN-13 3479775582412
Maximum Ampacity Ratings
Cross Section (mm²/kcmil) ΔT 30° C (A) ΔT 40° C (A) ΔT 45° C (A) ΔT 50° C (A) ΔT 55° C (A) ΔT 60° C (A) ΔT 70° C (A) 2 Bar Current Coefficient 3 Bar Current Coefficient
25/49.34 137 158 167 177 185 193 209 1.6 2
50/98.68 213 246 260 274 288 301 325 1.6 2
Circuit Breaker Compatibility
Circuit Breaker Current Rating 125/160 A 250 A
Part Number IBS25x IBS50x
Schneider Electric® Compact® (IEC) NSX 100
NSX 160
NSX 250
Square D® PowerPact® (UL) J-Frame J-Frame
ABB® Tmax® (IEC) - T3
XT3
XT4
ABB® Tmax® (UL) T3 T4
GE® Record Plus® (IEC/UL) FE 160 FE 250
Siemens® Sentron® (IEC/UL) - VL250
3VL3
Moeller® xEnergy® (IEC) - NZM2
Cutler Hammer® Series G (UL) JG Frame JG Frame
Legrand® (IEC) - DPX 250
DPX3 250
Hager® (IEC) - h3 250
Rockwell/Allen Bradley (UL) - I-Frame
J-Frame
Mitsubishi Electric (IEC) NF125
NF160
DSN125
DSN160
NF250
DSN250
∆T = Temperature of conductors – Internal temperature of panel.
This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear.

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

ABB is a registered trademark of ABB Asea Brown Boveri Ltd.
ABS is a registered certification mark of American Bureau of Shipping.
CSA, CSA-US and C-CSA-US are registered trademarks of Canadian Standards Association.
GE and Record Plus are registered trademark of General Electric Company.
Hager is a registered trademark of the Hager Group.
IEC is a registered trademark of the International Electrotechnical Commission.
Legrand is a registered trademark of Legrand North America, Inc.
Moeller, xEnergy, and Cutler Hammer are registered trademarks of Eaton Corporation.
Schneider Electric and Compact are registered trademarks of Schneider Electric SA.
Siemens and Sentron are registered trademarks of Siemens Aktiengesellschaft.
Square D and PowerPact are registered trademarks of SNA Holdings Inc.
Tmax is a registered trademark of ABB SACE Spa.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Video

Brochures

Catalogs

Flexible Conductors
10.96 MB English

Certifications

CSA 90005
CSA C22.2 No. 0, CSA C22.2 No. 210
cUR QEUY8.E125470
CSA C22.2 No. 29, CSA C22.2 No. 244
IEC 61439-1 Class II IBS-IBSB-IBSBR
IEC 61439-1 (2011), EN 61439-1 (2012), 51 KB English
IEC 61439-1 IBS-IBSB-IBSBR
IEC 61439-1 (2012), 50 KB English
UR AVLV2.E316390
ANSI/UL 758
UR QEUY2.E125470
ANSI/UL 67, ANSI/UL 891

Datasheets