United StatesChange
nVent ERIFLEX

IBS Advanced Round Insulated Braided Conductor, Halogen Free

IBSADV120-430 (534515)

IBS Advanced Round Insulated Braided Conductor, Halogen Free are the ideal ready-to-install flexible wire replacement solution. Round IBS Advanced connect to the terminals of an electrical device without the need for additional accessories, such as angular connectors, spreaders, ring terminal connectors or extenders. Round IBS Advanced are available in cross sections of 120, 185 and 240 mm² (236.82, 365.10, and 473.65 kcmil), lengths from 330 to 1,030 mm (9.06" to 40.55"), and amperages ranging from 420 to 630 A.

Manufactured in an ISO 9001 certified automated facility, round IBS Advanced is formed by weaving high-quality electrolytic copper wire to form a durable low voltage connector with maximum flexibility that allows for more compact power connections to electrical devices. The round IBS Advanced allows users to reduce the total size and weight of the installation, improving both design flexibility and assembly aesthetics.

The round IBS Advanced features pre-punched palms that are ready to connect out of the box. There are no lugs to purchase or install, making connections simpler and faster and eliminating faulty connections due to vibration or fatigue.

The advanced technology insulation is a high-resistance low smoke, halogen-free and flame retardant thermoplastic.

Round IBS Advanced does not generate corrosive gases and produces a relatively low smoke opacity in accordance with IEC 61034-2 and UL 2885. The low smoke characteristic improves the visibility conditions for people to be able to easily locate the emergency exit and also allows rescue workers to better assess an emergency situation. Round IBS Advanced means greater safety for individuals, less damage for your electrical equipment and less environmental impact.

The halogen–free feature enables a reduction in the quantity of toxic smoke. Round IBS Advanced does not contain any halogens, according to IEC 60754-1 and UL 2885, minimizing toxicity and making it the ideal product for use in enclosed spaces such as data centers, rail, and public facilities such as hospitals and schools. This also facilitates the use of round IBS Advanced in specific applications such as submarines, switchboards and other enclosed environments that require a low emissions solution.

In addition to the above features, round IBS Advanced is also compliant with the UL 94-V0 testing standard and Glow wire test 960 °C. The flame retardant portion of the test illustrates the self-extinguish feature. This superior feature of round IBS Advanced is also shown by the Limiting Oxygen Index (LOI) at 30%. In case of fire, round IBS Advanced generates a limited quantity of smoke that is less damaging to your electrical equipment.

Features

  • Resistant to vibration, improving reliability and performance
  • Insulated by high-resistance, halogen free, flame retardant and low smoke material
  • Tinned copper provides superior corrosion resistance
  • Improves assembly flexibility and aesthetics
  • Quick and easy installation
  • No additional cutting, stripping, crimping and punching needed
  • Conforms to NF EN 45545 obtaining an HL2 classification for chapters R22 and R23
  • Small wire diameter provides maximum flexibility
  • Dramatically smaller and more flexible than comparable cable based on ampacity
  • Better power density than cable with lower skin effect ratio
  • Reduces total installation cost
  • RoHS compliant

Specifications

Part Number IBSADV120-430
Article Number 534515
Typical Application Current Rating 400 A
Material Copper
Thermoplastic Elastomer
Finish Tinned
Dielectric Strength 20 kV/mm
Flammability Rating UL® 94V-0
Halogen Free Rating UL® 2885
IEC® 60754-1
IEC® 62821-1
Low Smoke Rating IEC® 61034-2
ISO 5659-2
UL® 2885
Insulation Elongation 500 %
Insulation Thickness 0.07"
Max Working Voltage, IEC/UL 758 1,000 VAC
1,500 VDC
Max Working Voltage, UL 67 600 VAC/DC
Working Temperature -58 to 239 °F
Wire Diameter 0.006"
Certification Details UL® 67
UL® 758
Complies With IEC® 60439.1
IEC® 60695-2-11 (Glow Wire Test 960 °C)
IEC® 61439.1
IEC® 61439.1 Class II
Cross Section 236.82 kcmil
Conductor Width 0.94"
Conductor Thickness 0.39"
Length (L) 16.93"
A 0.47"
Diameter (Ø) 1.06"
Hole Size (HS) 0.41"
Certifications Bureau Veritas 41939 BV
CE
CSA 90005
cURus
DNV GL IBS/IBSB Advanced, TAE00003B8
IEC 61439-1 Class II IBSB_ADV
IEC 61439-1 IBSB_ADV
RoHS
Standard Packaging Quantity 2 pc
UPC 78285696141
EAN-13 0782856961413
Maximum Ampacity Ratings
Cross Section (mm²/kcmil) ΔT 30° C (A) ΔT 40° C (A) ΔT 45° C (A) ΔT 50° C (A) ΔT 55° C (A) ΔT 60° C (A) ΔT 70° C (A) 2 Bar Current Coefficient
120/236.82 325 376 398 420 441 460 497 1.6
185/365.10 407 470 499 526 552 576 622 1.6
240/473.65 488 563 598 630 661 690 745 1.6
∆T = Temperature of conductors – Internal temperature of panel.
This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear.

nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

CSA, CSA-US and C-CSA-US are registered trademarks of Canadian Standards Association.
IEC is a registered trademark of the International Electrotechnical Commission.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Certifications

Bureau Veritas 41939 BV
ACE 14/163/3, 393 KB English
CSA 90005
CSA C22.2 No. 0, CSA C22.2 No. 210
cUR QEUY8.E125470
CSA C22.2 No. 29, CSA C22.2 No. 244
DNV GL IBS/IBSB Advanced, TAE00003B8
DNV GL Rules, 245 KB English
IEC 61439-1 Class II IBSB_ADV
IEC 61439-1 Class II, 52 KB English
IEC 61439-1 IBSB_ADV
IEC 61439-1, 51 KB English
UR QEUY2.E125470
ANSI/UL 67, ANSI/UL 891

Engineering Specifications

Miscellaneous

Test Reports