United StatesChange
ERIFLEX

Cable to ERIFLEX FLEXIBAR/Insulated Power Braid Power Block

SBF400AL (561165)

Features

  • Directly connect ERIFLEX FLEXIBAR or insulated power braid on line side
  • Compact power block with high short circuit current rating
  • Tinned copper or aluminum block allows for copper or aluminum conductor connections
  • Screw retaining cover is hinged and removable
  • Design allows for visual inspection of conductor and confirmation of connection
  • Gangable for building multi-pole power blocks
  • Easily clips onto DIN rail or mounts to panel with screws
  • Voltage detection and measurement connection
  • 95% fill ratio
  • Halogen free
  • RoHS compliant

Specifications

Part Number SBF400AL
Article Number 561165
Finish Tinned
Material Aluminum
Thermoplastic
Max Current Rating, ERIFLEX FLEXIBAR, IEC 510 A
Max Current Rating, Insulated Power Braid, IEC 450 A
Max Current Rating, ERIFLEX FLEXIBAR, UL/CSA 335 A
Max Current Rating, Insulated Power Braid, UL/CSA 240 A
Peak Short Circuit Current (Ipk) 51 kA
Short Circuit Current Rating (SCCR) 100 kA
Max Working Voltage, IEC (Ui) 1,000 VAC
1,500 VDC
Max Working Voltage, UL (Vin) 1,000 VAC/DC
Line Side Number of Connections 1
Line Side Insulated Power Braid Cross Section 100 mm²
Load Side Number of Connections 1
Load Side Compact Stranded Wire Size 95 - 240 mm²
Load Side Wire Size 3/0 – 400 kcmil
Enclosure Rating IP 20
Depth (D) 3.23"
Height (H) 5.76"
Width (W) 1.63"
Unit Weight 0.59 lb
Certification Details UL® 1059
Flammability Rating UL® 94V-0
Complies With IEC® 60947-7-1
Certifications CE
cURus
RoHS
Standard Packaging Quantity 1 pc
UPC 78285691271
EAN-13 8711893155419
Line Side ERIFLEX FLEXIBAR Size
Part Number Number of Layers Conductor Width Lamination Thickness
SBF400 2 - 5 20 - 24 mm 1 mm
SBF630 2 - 8 20 - 32 mm 1 mm
Design Guideline for Distribution Blocks, Power Blocks and Power Terminals
Derating according to Ambient* Temperature (°F) to maintain working temperature of 185°F
Ambient Temperature (°F) 86° 95° 104° 113° 122° 131° 140° 149° 158° 167°
Derating Coefficient (d) 1 1 1 0.94 0.88 0.82 0.75 0.67 0.58 0.47
*environment around the terminal blocks inside the enclosure

Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

IEC is a registered trademark of the International Electrotechnical Commission.
UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC.

Applications

Video

Certifications

cUR XCFR8.E198301
CSA C22.2 No. 158
UR XCFR2.E198301
ANSI/UL 1059

Datasheets